72
en | Alarm
Camera Browser Interface
AM18-Q0649 | v5.8 | 2013.06
Software manual
Bosch Security Systems
3.
Enter the password in the
Destination password
field.
4.
Set the user password of all the remote stations to be
accessed using this password.
Setting destination 10 to the IP-address 0.0.0.0 overrides its
function as the tenth address to try.
11.1.5
Video transmission
If the device is operated behind a firewall, select
TCP (HTTP
port)
as the transfer protocol. For use in a local network, select
UDP
.
To enable multicast operation, select the
UDP
option for the
Video transmission
parameter here and on the
Network
page.
Note:
In the event of an alarm, a larger network bandwidth is
sometimes required for additional video streams (if multicast
operation is not possible).
11.1.6
Stream
Select a stream to be transmitted.
11.1.7
Remote port
Select an appropriate browser port depending on the network
configuration. The ports for HTTPS connections are only
available if the
On
option in
SSL encryption
is selected.
11.1.8
Video output
If a decoder device is used, select the analog video output to
which the signal should be switched. If the destination device is
unknown, select the
First available
option. This places the
image on the first video output with no signal.
The connected monitor only displays images when an alarm is
triggered.
11.1.9
Decoder
If a split image is set for the selected video output, select a
decoder to display the alarm image. The decoder selected
determines the position of the image.
Содержание FLEXIDOME corner 9000 MP
Страница 1: ...Camera Browser Interface FLEXIDOME corner 9000 MP en Software manual ...
Страница 2: ......
Страница 106: ...106 en Service Camera Browser Interface AM18 Q0649 v5 8 2013 06 Software manual Bosch Security Systems ...
Страница 107: ......
Страница 108: ...Bosch Security Systems www boschsecurity com Bosch Security Systems 2013 ...