24
5. CAMERA RE-ASSEMBLY
Make sure all wires are properly connected and
tightened into the terminal blocks, all holes are
sealed against moisture penetration, and all
mounting screws are tight.
Step 5.1 - Check that the large “
O
” ring gasket
in the camera base has not been
dislodged or distorted.
Step 5.2 - Gently press the camera dome in
place. Move the retaining ring over
the dome.
Step 5.3 - Use the protruding set-screws in the
retaining ring to carefully rotate the
ring clockwise until it is slightly snug,
but not so tight that the ring cannot
rotate further.
Step 5.4 - Press firmly on the dome and rotate
the retaining ring
until one of the
set-screws aligns with the
adhesive dot on the side of the
dome
. Tighten all set-screws with
the supplied Allen key. Refer to
Figure 5-1
on page 25.