User Programming Items

Item
No.

Programming Item

Range

861

Passcode Length

4 or 6 digits

862

User 22 Configuration

0 = User 22 is disabled
1 = User 22 is a duress user
2 = User 22 is a guard user

7001

Installer Passcode (User 0)

1111 to 555555

7011

Master User Passcode (User 1)

Control Center Programming Items

Item
No.

Programming Item

Range

888

Fire Button Alarm [1] key

0 = Disabled
1 = Enabled

889

Medical Button Alarm [1][2] keys

890

Panic Button Alarm [2] key

0 = Disabled
1 = Audible alarm
2 = Silent alarm

891

One Button Arming

0 = Disabled
1 = Enabled

892

Invalid Passcode Attempt Limit

3 to 8

893

Control Center Lockout Time

1 to 30 min

Easy Series Control Panel

Appendix | en

21

Bosch Security Systems, Inc.

Quick Start Guide

2014.09 | 01 | F.01U.306.216

Содержание Easy Series

Страница 1: ...Easy Series Control Panel ICP EZM2 en Quick Start Guide ...

Страница 2: ......

Страница 3: ...guring with RPS 8 4 Add Change Users 10 4 1 Add users 10 4 2 Change users 10 5 System Test and Maintenance 11 6 Installer Telephone Menu 12 7 Appendix 13 7 1 Expert Programming 13 7 2 Country Codes 23 7 3 Default Passcodes 23 Easy Series Control Panel Table of Contents en 3 Bosch Security Systems Inc Quick Start Guide 2014 09 01 F 01U 306 216 ...

Страница 4: ...uch the earth ground terminal on the control panel board to discharge any static charge before working on the control panel board If you install more than one control center mount them at least 1 2 m apart Do not install the RADION receiver within 15 cm 6 in of the control centers metal enclosure 12 VDC 2 3 4 5 6 1 7 Figure 1 1 System component placement in enclosure 1 4 en Install the Enclosure E...

Страница 5: ...witch 3 Ground connection Connect ground wire from enclosure to enclosure door 4 Module mounting location 5 Module mounting location 6 Status LED System Test Button 7 Port for ICP EZV2 Voice Module Easy Series Control Panel Install the Enclosure en 5 Bosch Security Systems Inc Quick Start Guide 2014 09 01 F 01U 306 216 ...

Страница 6: ...tion 1 Control Center Mount within 3 m of control panel Use CAT5 cable twisted pair for audio bus Set data bus address 1 4 up to 4 controls max 2 RADION receiver 1 Normal Operation 5 Maintenance Mode 3 DX2010 Point Expander Data bus Adr 102 Points 9 16 Data bus Adr 103 Points 17 24 Data Bus Adr 104 Points 25 32 2 6 en Wire the Control Panel Easy Series Control Panel 2014 09 01 F 01U 306 216 Quick ...

Страница 7: ...rior burglary alarm 11 2 wire Smoke Detector Option EOL resistor P N 25899 required 12 4 wire Smoke Detector Option EOL resistor P N 25899 and Bosch EOL relay module required Note The system uses a 12 VDC battery connected as shown If using RADION devices 1 Mount the bases for the wireless devices in the desired locations Do not attach the wireless devices to the bases at this time 2 Remove all po...

Страница 8: ... number is currently assigned to a Wireless ID To set Point Type press 1 To replace a device press 3 To delete this device press 4 Press to exit 1 Press to exit to the main menu 2 Press 2 to enter the User Menu to change the installer passcode 3 Press 1 and change the Installer Passcode 4 Press to exit the User Menu Configuring with RPS In addition to the Installer Phone Menu you may use RPS to co...

Страница 9: ...e detector Smoke detector RFSM Smoke Door Window contact sensor Universal transmitter RFUN Wired or magnet Glass break sensor Glassbreak detector RFGB Glass break Wireless Recessed Point Recessed door window contact RFDW RM Magnet Wireless Bill Clip Bill trap RFBT Magnet Mini Door Window contact Door window contact RFDW SM Magnetic Notice Do not use any other RPS device types when specifying RADIO...

Страница 10: ...w user 5 Repeat step 4 for additional users Press to return to the User Menu or to exit completely Change users Change Users 1 Enter the User Telephone Menu 2 Enter the Master User User 1 passcode 3 Press 4 to enter the User Menu 4 Press 2 to change a user Press 2 repeatedly until the system speaks the desired user number 5 Repeat Step 4 in Add Users 6 Press to return to the User Menu or to exit c...

Страница 11: ...ring station CMS to verify that all necessary test reports were received including test reports from all installed input and output devices Notice After system installation and any control panel programming perform a complete system test A complete system test includes testing the control panel all devices and communication destinations for proper operation 5 Easy Series Control Panel System Test ...

Страница 12: ...t 2 1 Enter account number Configure report destinations Remote programming success Exit 2 3 1 Exit Outputs Country code 3 4 Select output function Exit 1 Expert Programming 4 Enter programming item enter selection Two Way Voice Session 5 Talk to person at control center Listen to person at control center Exit 2 1 Custom Messages 6 Record site description Record Call for Service message Exit 2 1 P...

Страница 13: ...10 min 114 Chime Tone Select 1 2 or 3 115 Chime Mode Operation After System Off 0 Off 1 On 2 Follows previous setting 116 Automatic Test Frequency Report 0 Off 1 Daily 2 Weekly 3 Monthly 119 EN50131 Level 4 Access Code 6 digit numerical passcode 0 9 121 Daylight Saving Time 0 Off 1 North America pre 2007 2 Europe Asia 3 Tasmania Australia 4 Rest of Australia 5 New Zealand 6 Cuba 7 South America An...

Страница 14: ...ser only 140 Demo Mode 0 The system only speaks all telephone messages over the phone 1 The system speaks all telephone messages over the phone and at all control centers connected to the system 2 During telephone programming press the i button to turn message announcements on or off at the control center 142 Restrict Installer Passcode 0 Master user not needed 1 Master user needed 151 Wireless De...

Страница 15: ...ror 0 Off normal points create an exit error at the end of Exit Delay 1 Off normal points are force armed at the end of Exit Delay 168 Audio Verification Command Set 0 Use SIA Standard Audio Verification commands AV 01 1997 11 1 Use alternate audio verification command set 601 Enable Keyfob Duress 0 Wireless keyfob does not send a Duress event 1 Wireless keyfob sends a Duress event Audio Verificat...

Страница 16: ...ct 0 On 1 Off Phone Number IP Address for Route Destination 206 Route 1 Primary 32 digits maximum 0 9 B F allowed between each IP address notation Exit with save Exit without save Disable phone number 0 Disable IP address 240 0 0 0 207 Route 1 Backup 208 Route 2 Primary 209 Route 2 Backup 210 SMS Service Provider No Format for Route Destination 211 Route 1 Primary 0 Disabled 1 Contact ID 2 SIA 3 V...

Страница 17: ...r Route Destination 281 Route 1 Primary 0 Disabled 1 to 65535 min 282 Route 1 Backup 283 Route 2 Primary 284 Route 2 Backup Acknowledge Wait Time for Destination 285 Route 1 Primary 5 to 255 sec 286 Route 1 Backup 287 Route 2 Primary 288 Route 2 Backup Anti Replay for Route Destination 289 Route 1 Primary 0 Disabled 1 Enabled 290 Route 1 Backup 291 Route 2 Primary 292 Route 2 Backup Heartbeat Atte...

Страница 18: ...atic Call in Phone Number IP Address Refer to Item Numbers 206 209 for allowed entries 245 RPS Automatic Call in Method 0 Phone number 1 IP address 246 RPS Port Number 0 to 655353 Point Report and Restoral Routing Item No Programming Item Item No Programming Item 301 Point Reports and Restorals all 326 Intrusion Zone Bypass 307 Intrusion Alarm 327 Intrusion Zone Bypass Restoral 308 Intrusion Alarm...

Страница 19: ...gramming Item 302 System On and Off Reports all 341 Open 314 Exit Error 342 Open Keyswitch 330 Recent Closing 343 Open Remote 337 Close System On Unoccupied 344 Close System On Custom 338 Close System On Occupied 386 Open by Guard Code 339 Close Keyswitch 403 Partial Close System On 340 Close Remote Range 0 Neither Route 1 Route 1 only 2 Route 2 only 3 Both routes System Report and Restoral Routin...

Страница 20: ...upervision Fail 384 RAM Checksum Failed 354 Control Center Supervision Restoral 385 System Inactive 355 Control Center Tamper 391 Passcode Tamper 356 Control Center Tamper Restoral 392 Watchdog Reset 357 Local Programming Success 410 Date Time Changed 362 Communication Test Manual 413 Network Fail 363 Phone Line Fault 414 Network Restoral Range 0 Neither Route 1 Route 1 only 2 Route 2 only 3 Both ...

Страница 21: ...ser 1 Control Center Programming Items Item No Programming Item Range 888 Fire Button Alarm 1 key 0 Disabled 1 Enabled 889 Medical Button Alarm 1 2 keys 890 Panic Button Alarm 2 key 0 Disabled 1 Audible alarm 2 Silent alarm 891 One Button Arming 0 Disabled 1 Enabled 892 Invalid Passcode Attempt Limit 3 to 8 893 Control Center Lockout Time 1 to 30 min Easy Series Control Panel Appendix en 21 Bosch ...

Страница 22: ...Momentary Keyswitch 12 Maintained Keyswitch 13 24 Trouble 14 User Emergency Circuit Style Point 01 9012 Point 32 9322 0 Dual 2 2 kΩalarm and tamper circuit 1 Single 2 2 kΩalarm circuit Alarm Verification Point 01 9016 Point 32 9326 0 Disable audio alarm verification 1 Enable audio alarm verification Programming Item Item No Factory Default 9999 22 en Appendix Easy Series Control Panel 2014 09 01 F...

Страница 23: ... 54 Canada 07 Italy 25 Thailand 55 China 08 Japan 26 Turkey 56 Croatia 10 Lithuania 29 Ukraine 62 Czech Republic 12 Luxembourg 20 United Arab Emirates 65 Denmark 13 Malaysia 32 United Kingdom 57 Egypt 14 Mexico 34 United States 58 Finland 16 Netherlands 35 France 17 New Zealand 36 Default Passcodes Passcode Default Installer Passcode User 0 5432 11 Master User User 1 1234 55 Guard Code User 22 111...

Страница 24: ...Bosch Security Systems Inc 130 Perinton Parkway Fairport NY 14450 USA www boschsecurity com Bosch Security Systems Inc 2014 Bosch Sicherheitssysteme GmbH Robert Bosch Ring 5 85630 Grasbrunn Germany ...

Отзывы: