Point Report and Restoral Routing
Item
No.
Programming Item
Item
No.
Programming Item
313
Duress
336
Supervisory Alarm Restoral
315
Fire Alarm
371
Fire Cancel
316
Fire Alarm Unverified
388
Point Tamper
317
Fire Alarm Restoral
393
Cross Zone Trouble
318
Panic
394
Alarm Recent Close
323
Cancel
399
Panic Restoral
324
Intrusion Trouble
400
Cross Zone Trouble Restoral
325
Intrusion Trouble Restoral
Range: 0 = Neither Route, 1 = Route 1 only, 2 = Route 2 only, 3 = Both
routes
System On and Off (Open and Close) Report Routing
Item
No.
Programming Item
Item
No.
Programming Item
302
System On and Off Reports
(all)
341
Open
314
Exit Error
342
Open Keyswitch
330
Recent Closing
343
Open Remote
337
Close (System On)
Unoccupied
344
Close (System On) Custom
338
Close (System On)
Occupied
386
Open by Guard Code
339
Close Keyswitch
403
Partial Close (System On)
340
Close Remote
Range: 0 = Neither Route, 1 = Route 1 only, 2 = Route 2 only, 3 = Both
routes
System Report and Restoral Routing
Item
No.
Programming Item
Item
No.
Programming Item
303
System Reports and
Restorals (all)
358
Low Battery
319
User Emergency
359
Low Battery Restoral
320
User Fire
364
Phone Line Fault Restoral
321
User Fire Restoral
372
Firmware Updated
Easy Series Control Panel
Appendix | en
19
Bosch Security Systems, Inc.
Quick Start Guide
2014.09 | 01 | F.01U.306.216
Содержание Easy Series
Страница 1: ...Easy Series Control Panel ICP EZM2 en Quick Start Guide ...