background image

11

Finishing installation of the appliance

1.

Drill an 8 mm Ø hole to a depth of 80 mm for the safety 

screw and press the wall plug flush into the wall.

 ¨

2.

Initially remove the protective foil from the back of the 

appliance and, following installation, remove the foil 

completely.

3.

Attach the appliance.

©

4.

Screw in the safety screw - and washer - and tighten all the 

screws. 

ª

Connecting the appliance to the power supply

Connecting the air extractor

Note: 

If using an aluminium pipe, smooth the connection area 

beforehand.

1.

Attach the air extractor pipe directly to the air-pipe connector.

2.

Connect to air extractor opening.

3.

Seal the joints appropriately.

Connect the power supply

1.

Plug the mains plug into the earthed socket.

2.

If a fixed connection is required, please follow the instructions 

in the 

Electrical Connection

 section.

Attaching the flue duct

Risk of injury!

Components inside the appliance may have sharp edges. Wear 
protective gloves.

1.

Separate the flue ducts. 
To do this, remove the adhesive tape

2.

Remove the protective foil from both flue ducts.

3.

Push one flue duct into the other.

Notes

To prevent scratches, lay paper over the edges of the outer 

flue duct to protect the surface.

– Slots of the inner flue duct point downwards.

4.

Place the flue ducts on the appliance.

5.

Push the inner flue duct upwards and attach it to the fixing 

brackets on the left and right. 

¨

6.

Press the flue duct downwards until it engages. 

©

7.

Screw the flue duct to the sides of the fixing bracket using 

two screws. 

ª

$

%

&

[

$

%

&

Содержание DWB06W452B

Страница 1: ......

Страница 2: ......

Страница 3: ......

Страница 4: ......

Страница 5: ......

Страница 6: ......

Страница 7: ......

Страница 8: ......

Страница 9: ......

Страница 10: ......

Страница 11: ......

Страница 12: ......

Отзывы: