background image

9

Safe operation is possible only when the 

partial vacuum in the place where the heat-

producing appliance is installed does not 

exceed 4 Pa (0.04 mbar). This can be 

achieved when the air needed for 

combustion is able to enter through 

openings that cannot be sealed, for 

example in doors, windows, incoming/

exhaust air wall boxes or by other technical 

means.

In any case, consult your responsible 

Master Chimney Sweep. He is able to 

assess the house's entire ventilation setup 

and will suggest the suitable ventilation 

measures to you.
Unrestricted operation is possible if the 

vapour extractor hood is operated 

exclusively in the circulating-air mode.

Danger of death!

Risk of poisoning from flue gases that are 

drawn back in. If installing a ventilation 

system in a room with a heat-producing 

appliance connected to a chimney/flue, the 

electricity supply to the hood must be 

equipped with a suitable safety switch.

Risk of fire!

Grease deposits in the grease filter may 

catch fire. The specified safety distances 

must be observed in order to prevent an 

accumulation of heat. Observe the 

specifications for your cooking appliance. If 

gas and electric hobs are operated 

together, the largest specified distance 

applies.
Only one side of the appliance may be 

installed directly next to a high-sided unit or 

a wall. The distance between the appliance 

and wall or high-sided unit must be at least 

50 mm. 

Risk of injury!

Components inside the appliance may 

have sharp edges. Wear protective gloves.

Risk of in jury!

The appliance may fall from the wall if it is 

not attached properly. All fastening 

components must be fixed firmly and 

securely in place.

Risk of in jury!

The appliance is heavy. To move the 

appliance, 2 people are required. Use only 

suitable tools and equipment.

Risk of electric shock!

Components inside the appliance may have 

sharp edges. These may damage the 

connecting cable. Do not kink or pinch the 

connecting cable during installation.

Danger of suffocation!

Packaging material is dangerous to 

children. Never allow children to play with 

packaging material.

General information

Exhaust air mode

Note: 

The exhaust air must not be conveyed into a functioning 

smoke or exhaust gas flue or into a shaft which is used to 

ventilate installation rooms which contain heat-producing 

appliances.

Before conveying the exhaust air into a non-functioning 

smoke or exhaust gas flue, obtain the consent of the heating 

engineer responsible.

If the exhaust air is conveyed through the outer wall, a 

telescopic wall box should be used.

Exhaust duct

Note: 

The appliance manufacturer does not assume any 

warranty for complaints attributable to the pipe section.

The appliance achieves its optimum performance by means 

of a short, straight exhaust air pipe and as large a pipe 

diameter as possible.

Because of long rough exhaust air pipes, many of which are 

pipe bends or have diameters smaller than 150 mm, the 

optimum extraction performance is not achieved and fan 

noise is increased.

The pipes or hoses for laying the exhaust duct must consist 

of non-combustible material.

Round pipes

An inner diameter of 150 mm, but at least 120 mm, is 

recommended.

Flat ducts

The inner cross-section must correspond to the diameter of the 

round pipes.

Ø 150 mm approx. 177 cm

2

Ø 120 mm approx. 113 cm

2

Flat ducts should have no sharp deflections.

Use sealing strip for deviating pipe diameters.