Intensive setting

You can use the intensive setting if there is a large build-up of 

odours and fumes/vapours.
Press the + button when the fan is at setting 

.

The intensive boost setting

 is activated. Pressing the + button 

again activates the intensive boost 

ƒ

setting.

After approx. six minutes, the electronics automatically reduce 

the fan to a lower setting . If you want to end the intensive 

setting before the preset time expires, press the - button until 

the required fan setting is reached.

Fan run-on time

The fan run-on time is possible at every fan setting (except 

boost

 and boost 

ƒ

).

Select the desired fan setting and press the 

r

 button. 

Š

min

r

 appears on the display.

Once this time has elapsed, the fan switches off automatically.

Setting the run-on time

When 

Š

min

 appears on the display, press the + or - button.

You can set a run-on time of between 1 and 9 minutes.

Lighting

The lighting can be switched on and off independently of the 

fan.
Press the 

B

 button.

Setting the brightness

Press and hold the 

B

 button until the desired brightness is 

reached.

Saturation display

When the metal mesh grease filters or the activated carbon 

filter are saturated, a signal sounds for approx. 4 seconds after 

the fan is switched off.
In addition, the corresponding symbol appears in the display:  

Metal mesh grease filter:

 #

Activated carbon filter: 

#

If you have not yet done so, the metal mesh grease filters 

should be cleaned or the activated carbon filter changed now. 
For instructions on how to clean the metal mesh grease filters, 

please refer to the section 

Cleaning and maintenance

.

While the saturation displays are flashing, they can be reset. To 

do this, press the 

#

 button.

Switching over the display for circulating-air mode

For circulating-air mode, the electronic control display must be 

switched over accordingly:

The extractor hood must be connected and switched off.

Press the 

%

 and 

r

 buttons at the same time until the

display for starter sets for circulating-air mode or

#

 display for CleanAir circulating air modules

lights up.

Repeatedly press the button combination to switch the 

electronic control display back to exhaust air mode (

#

 

display).

Audible signal 

Switching on the acoustic signal

When the fan is switched off, press the 

 and + buttons at the 

same time for approx. three seconds. An acknowledgement 

signal sounds.

Switching off the acoustic signal

Repeat the "Switching on the acoustic signal" process.

Control panel model 3

Control panel

Setting the fan

Switching on the appliance

Press the 

%

 button.

The fan starts at setting 

ƒ

.

Press the + or - button to change the fan strength.

Switching off

Press the 

%

 button.

Intensive setting

You can use the intensive setting if there is a large build-up of 

odours and fumes/vapours.
Press the + button when the fan is at setting 

.

The intensive boost setting

 is activated. Pressing the + button 

again activates the intensive boost 

ƒ

setting.

After approx. six minutes, the electronics automatically reduce 

the fan to a lower setting . If you want to end the intensive 

setting before the preset time expires, press the - button until 

the required fan setting is reached.

Automatic mode

Switching on the appliance

Press the 

%

 button.

The fan starts at 

ƒ

 setting.

Press the 

1

 button.

The optimum fan setting 

ƒ

 or 

 is automatically set via a 

sensor.

Switching off the appliance

Press the 

1

 or 

%

 button to switch off automatic mode.

The fan switches off automatically if the sensor no longer 

detects a change in the air quality of the room.
The automatic mode lasts 4 hours at most.

Sensor control

In automatic mode, a sensor in the extractor hood detects the 

intensity of the cooking and roasting fumes. Depending on the 

setting of the sensor, the fan automatically switches to another 

fan setting.
Default sensitivity setting: 

Lowest sensitivity setting: 

Highest sensitivity setting: 

Š

If the sensor control responds too quickly or too slowly, it can 

be changed accordingly:

Explanation

%

Fan on/off

1

Eco function (automatic mode)

 -

Reduce the fan settings

 +

Increase the fan settings/intensive setting 1, 2

r

Fan run-on time

B

Light on/off/dimming

HFR

ERRVW

HFR

Содержание DWA097E51B

Страница 1: ... en Instructions for installation and use Extractor hood ...

Страница 2: ...ate your appliance safely and correctly Retain the instruction manual and installation instructions for future use or for subsequent owners The appliance can only be used safely if it is correctly installed according to the safety instructions The installer is responsible for ensuring that the appliance works perfectly at its installation location This appliance is intended for domestic use and th...

Страница 3: ...Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating air mode Risk of fire Grease deposits in the grease filter may catch fire Clean the grease filter at least every 2 months Never operate the appliance without the grease fi...

Страница 4: ... strong and abrasive cleaning agents Risk of damage from returning condensate Install the exhaust duct in such a way that it falls away from the appliance slightly 1 slope Environmental protection Unpack the appliance and dispose of the packaging in an environmentally responsible manner Environmental protection Operating modes This appliance can be used in exhaust air mode or circulating air mode ...

Страница 5: ...d off In addition the corresponding symbol appears in the display Metal mesh grease filter Activated carbon filter If you have not yet done so the metal mesh grease filters should be cleaned or the activated carbon filter changed now For instructions on how to clean the metal mesh grease filters please refer to the section Cleaning and maintenance While the saturation displays are flashing they ca...

Страница 6: ...sets for circulating air mode or display for CleanAir circulating air modules lights up Repeatedly press the button combination to switch the electronic control display back to exhaust air mode display Audible signal Switching on the acoustic signal When the fan is switched off press the and buttons at the same time for approx three seconds An acknowledgement signal sounds Switching off the acoust...

Страница 7: ...acoustic signal When the fan is switched off press the and buttons at the same time for approx three seconds An acknowledgement signal sounds Switching off the acoustic signal Repeat the Switching on the acoustic signal process Cleaning and maintenance Risk of burns The appliance will become hot during operation especially near the bulbs Allow the appliance to cool down before cleaning Risk of ele...

Страница 8: ...rease solvent for stubborn dirt It can be ordered via the Online Shop Soak the metal mesh grease filters in a hot soapy solution Clean the filters with a brush and then rinse them thoroughly Leave the metal mesh grease filters to drain Removing metal mesh grease filter 1 Open the lock and fold down the metal grease filter While doing this place the other hand under the metal grease filter 2 Take t...

Страница 9: ...ice Our after sales service is there for you if your appliance needs to be repaired We will always find the right solution in order to avoid unnecessary visits from a service technician When calling us please give the product number E no and the production number FD no so that we can provide you with the correct advice The rating plate with these numbers can be found inside the appliance remove th...

Страница 10: ...Throw away filter Basic equipment Starter set for circulating air mode wide Throw away filter Basic equipment CleanAir recirculation module narrow Throw away filter Basic equipment CleanAir recirculation module wide Throw away filter 1 2 3 4 5 6 7 8 1 DHZ 5325 channel width 260 mm 2 DHZ 5326 channel width 260 mm 3 DHZ 5345 channel width 345 mm 4 DHZ 5346 channel width 345 mm 5 DSZ 6200 channel wid...

Страница 11: ...orrespond at least with the width of the hob For the installation observe the currently valid building regulations and the regulations of the local electricity and gas suppliers When conveying the exhaust air official and legal regulations e g state building regulations must be followed Risk of death Risk of poisoning from flue gases that are drawn back in The exhaust air must not be conveyed into...

Страница 12: ...ney flue the electricity supply to the hood must be equipped with a suitable safety switch Risk of fire Grease deposits in the grease filter may catch fire The specified safety distances must be observed in order to prevent an accumulation of heat Observe the specifications for your cooking appliance If gas and electric hobs are operated together the largest specified distance applies Only one sid...

Страница 13: ...es must be the same length as the screws The wall plugs must have a secure grip The enclosed screws and wall plugs are suitable for solid brickwork Suitable fasteners must be used for other structures e g plasterboard porous concrete poroton bricks The max weight of the extractor hood is 40 kg Electrical connection Risk of electric shock Components inside the appliance may have sharp edges These m...

Страница 14: ...protective foil from the back of the appliance and following installation remove the foil completely 2 When attaching the appliance ensure that it engages firmly with the brackets 3 Align the appliance horizontally by turning the brackets If required the appliance can be moved to the right or left Securing the appliance 1 Press the safety caps with the arrow upwards onto the brackets until they en...

Страница 15: ...aching the flue duct Risk of injury From sharp edges during installation Always wear protective gloves while installing the appliance 1 Separate the flue ducts To do this remove the adhesive tape 2 Remove the protective foil from both flue ducts 3 Push one flue duct into the other Notes To prevent scratches lay paper over the edges of the lower flue duct to protect the surface Slots of the inner f...

Страница 16: ... 9000852654 9000852654 Robert Bosch Hausgeräte GmbH Carl Wery Straße 34 81739 München Germany www bosch home com ...

Отзывы: