background image

4

Risk of electric shock!

A defective appliance may cause electric 

shock. Never switch on a defective 

appliance. Unplug the appliance from the 

mains or switch off the circuit breaker in 

the fuse box. Contact the after-sales 

service.

Risk of electric shock!

Incorrect repairs are dangerous. Repairs 

may only be carried out and damaged 

power cables replaced by one of our 

trained after-sales technicians. If the 

appliance is defective, unplug the 

appliance from the mains or switch off the 

circuit breaker in the fuse box. Contact the 

after-sales service.

Risk of electric shock!

Do not use any high-pressure cleaners or 

steam cleaners, which can result in an 

electric shock.

Causes of damage

Caution!

Risk of damage due to corrosion. Always switch on the 

appliance while cooking to avoid condensation. Condensate 

can produce corrosion damage.
Always replace faulty bulbs to prevent the remaining bulbs from 

overloading.
Risk of damage due to ingress of humidity into the electronic 

circuitry. Never clean operator controls with a wet cloth.
Surface damage due to incorrect cleaning. Clean stainless 

steel surfaces in the direction of the grain only. Do not use any 

stainless steel cleaners for operator controls.
Surface damage due to strong or abrasive cleaning agents. 

Never use strong and abrasive cleaning agents.
Risk of damage from returning condensate. Install the exhaust 

duct in such a way that it falls away from the appliance slightly 

(1° slope).

Environmental protection

Unpack the appliance and dispose of the packaging in an 

environmentally-responsible manner.

Environmentally-friendly disposal

Dispose of packaging in an environmentally-friendly manner.

Operating modes

This appliance can be used in exhaust-air mode or circulating-

air mode.

Exhaust air mode

Note: 

The exhaust air must not be conveyed into a functioning 

smoke or exhaust gas flue or into a shaft which is used to 

ventilate installation rooms which contain heat-producing 

appliances.

Before conveying the exhaust air into a non-functioning 

smoke or exhaust gas flue, obtain the consent of the heating 

engineer responsible.

If the exhaust air is conveyed through the outer wall, a 

telescopic wall box should be used.

Circulating-air mode

Note: 

To bind odours in circulating-air mode, you must install 

an activated carbon filter. The different options for operating the 

appliance in circulating-air mode can be found in the brochure. 

Alternatively, ask your dealer. The required accessories are 

available from specialist outlets, from customer service or from 

the Online Shop. The accessory numbers can be found at the 

end of the instructions for use.

This appliance is labelled in accordance with 

European Directive 2012/19/EU concerning used 

electrical and electronic appliances (waste 

electrical and electronic equipment - WEEE). The 

guideline determines the framework for the return 

and recycling of used appliances as applicable 

throughout the EU.

The air which is drawn in is cleaned by the 

grease filters and conveyed to the exterior 

by a pipe system.

The air which is drawn in is cleaned by the 

grease filters and an activated carbon filter and 

conveyed back into the kitchen.

Содержание DWA064W50B

Страница 1: ... en Instructions for installation and use Extractor hood ...

Страница 2: ...ctly at its installation location This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable for damage which is caused by improper use or incorrect operation This appliance may be used by children over the age of 8 years old and by persons with re...

Страница 3: ...lter may catch fire Clean the grease filter at least every 2 months Never operate the appliance without the grease filter Risk of fire Grease deposits in the grease filter may catch fire Never work with naked flames close to the appliance e g flambéing Do not install the appliance near a heat producing appliance for solid fuel e g wood or coal unless a closed non removable cover is available There...

Страница 4: ...npack the appliance and dispose of the packaging in an environmentally responsible manner Environmentally friendly disposal Dispose of packaging in an environmentally friendly manner Operating modes This appliance can be used in exhaust air mode or circulating air mode Exhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is u...

Страница 5: ...ts Observe the information in the table to ensure that the different surfaces are not damaged by using the wrong type of cleaning agent Do not use harsh or abrasive cleaning agents cleaning agents with a high concentration of alcohol hard scouring pads or sponges high pressure cleaners or steam cleaners Wash new sponge cloths thoroughly before use Follow all instructions and warnings included with...

Страница 6: ...ase filters loosely in the dishwasher The metal mesh grease filters must not be wedged in By hand Note You can use a special grease solvent for stubborn dirt It can be ordered via the Online Shop Soak the metal mesh grease filters in a hot soapy solution Clean the filters with a brush and then rinse them thoroughly Leave the metal mesh grease filters to drain Removing metal grease filter 1 Open th...

Страница 7: ...remove the metal mesh grease filter Replacing halogen bulbs Note When inserting halogen bulbs do not touch the glass tube Use a clean cloth to insert the halogen bulbs 1 Carefully remove the bulb ring using a suitable tool 2 Pull out the bulb and replace it with a bulb of the same type 3 Insert the bulb cover 4 Insert the mains plug or switch on the fuse again Replacing filament bulbs 1 Lift the b...

Страница 8: ...n after sales engineer will be charged if a problem turns out to be the result of operator error even during the warranty period Please find the contact data of all countries in the enclosed customer service list To book an engineer visit and product advice Rely on the professionalism of the manufacturer You can therefore be sure that the repair is carried out by trained service technicians who ca...

Страница 9: ...ood must correspond at least with the width of the hob For the installation observe the currently valid building regulations and the regulations of the local electricity and gas suppliers When conveying the exhaust air official and legal regulations e g state building regulations must be followed Risk of death Risk of poisoning from flue gases that are drawn back in The exhaust air must not be con...

Страница 10: ...ney flue the electricity supply to the hood must be equipped with a suitable safety switch Risk of fire Grease deposits in the grease filter may catch fire The specified safety distances must be observed in order to prevent an accumulation of heat Observe the specifications for your cooking appliance If gas and electric hobs are operated together the largest specified distance applies Only one sid...

Страница 11: ... dia 120 mm ca 113 cm2 Flat ducts should not have any sharp deflections Use sealing strips for deviating pipe diameters Checking the wall The wall must be level vertical and adequately load bearing The depth of the bore holes must be the same length as the screws The wall plugs must have a secure grip The enclosed screws and wall plugs are suitable for solid brickwork Suitable fasteners must be us...

Страница 12: ...the wall 4 Screw on the fixing bracket for the flue duct 5 Screw in 2 securing screws with washers to approx 5 mm ª Installation 1 Attaching and aligning the appliance 2 Mark the hole for the safety screw 3 Remove the appliance once more ª Finishing installation of the appliance 1 Drill an 8 mm Ø hole to a depth of 80 mm for the safety screw and press the wall plug flush into the wall 2 Initially ...

Страница 13: ...aching the flue duct Risk of injury Components inside the appliance may have sharp edges Wear protective gloves 1 Separate the flue ducts To do this remove the adhesive tape 2 Remove the protective foil from both flue ducts 3 Push one flue duct into the other Notes To prevent scratches lay paper over the edges of the outer flue duct to protect the surface Slots of the inner flue duct point downwar...

Страница 14: ......

Страница 15: ......

Страница 16: ...940611 9000773694 9000773694 Robert Bosch Hausgeräte GmbH Carl Wery Straße 34 81739 München Germany www bosch home com ...