32
en | Technical Data
DSDA iSCSI Disk Array Series
V 1 | 2008.08
Installation Guide
Bosch Security Systems
8.2
Technical Specifications DSA-N2B20
8.2.1
Electrical Requirements – One Controller Module
8.2.2
System Hardware Specifications
8.2.3
Mechanical
8.2.4
Space Requirements
8.2.5
Environmental
Input voltage: 100 to 120V
Worst case,
single PSU
System,
two PSUs
• input current measured
3.37 A
3.22 A
• input power measured
332 W
316 W
• thermal dissipation
1133 BTU/hr
1077 BTU/hr
Input voltage: 200 to 240V
Worst case,
single PSU
System,
two PSUs
• input current measured
1.69 A
1.66 A
• input power measured
327 W
305 W
• thermal dissipation
1114 BTU/hr
1039 BTU/hr
Input power frequency
50 to 60 Hz
50 to 60 Hz
Chassis
2U, 19” rack-mountable
Power supplies
Dual redundant, hot pluggable
Max disk drives
12 x 750 GB SATA II drives
Max raw Capacity
9 TB
DDR2 memory (System RAM)
1024 MB
Nonvolatile SDRAM (NVRAM)
256 MB - protects “in flight” transactions
for 3 days in the event of a power loss.
Integrated I/O
2 Ethernet 10/100/1000 Copper
Remote management (via LAN)
Yes
Dimensions (H x W x D)
89 x 447 x 572 mm
(3.5 x 17.6 x 22.5 in)
Weight
27.215 kg (60 lb) full
Front–cooling
152 mm (6 in)
Rear–cooling
305 mm (12 in)
Front of chassis–maintenance
762 mm (30 in)
Rear of chassis–maintenance
915 mm (36 in)
Operating temperature
+10 °C to +40 °C (+50 °F to +104 °F)
Nonoperating temperature
-40 °C to +60 °C (-40 °F to +140 °F)
Relative humidity
20 to 80% noncondensing
Acoustic level
N/A
Содержание DSDA ISCSI DISK ARRAY SERIES DSA-N2B20
Страница 1: ...DSDA iSCSI Disk Array Series DSA S5B50 DSA N2B20 DSA N2B50 en Installation Guide ...
Страница 2: ......
Страница 38: ...36 en Trademarks DSDA iSCSI Disk Array Series V 1 2008 08 Installation Guide Bosch Security Systems ...
Страница 39: ......