![Bosch DSDA ISCSI DISK ARRAY SERIES DSA-N2B20 Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/bosch/dsda-iscsi-disk-array-series-dsa-n2b20/dsda-iscsi-disk-array-series-dsa-n2b20_installation-manual_41263015.webp)
DSDA iSCSI Disk Array Series
Configuration through the Web Interface | en
13
Bosch Security Systems
Installation Guide
V 1 | 2008.08
27. The changes are summarized on the
Commit
screen.
Click
Commit
to apply the new settings.
By default, one disk is left as a spare disk. If no spare disk is needed, this disk can be
added to the volume manually. To do so, please continue with step 28.
If you would like to keep the spare disk, please continue with step 32.
28. In the navigation panel, select
Filer
>
Use Command Line
.
29. Enter
vol add vol0 1
(or replace vol0 with the volume to which you want to add the disk).
30. A warning displays. Enter
y
(yes) to confirm the action.
A message confirms that the disk has been added.
31. Click
Disconnect
to disconnect from the command line console.
!
CAUTION!
If the settings made here are altered later, all data stored on the disks is lost as the RAID
group needs to be reconstructed.
Содержание DSDA ISCSI DISK ARRAY SERIES DSA-N2B20