DSDA Digital Storage Disk Arrays
Technical Data | en
33
Bosch Sicherheitssysteme GmbH
Installation Guide
- | V2 | 2009.11
9.1.4
Disk Shelf Expansion Unit - DSX-N2X00-14AT
9.2
Mechanical Specifications
9.2.1
System Hardware Specifications - DSA-N2B20
9.2.2
System Hardware Specifications - DSA-N2B40
9.2.3
System Hardware Specifications - DSA-N2B50
Input voltage: 100 to 120V
Worst case, single
PSU
System,2 PSUs
–
input current measured
3.42 A
3.22 A
–
input power measured
341 W
321 W
–
thermal dissipation
1163 BTU/hr
1095 BTU/hr
Input voltage: 200 to 240V
Worst case, single
PSU
System, 2 PSUs
–
input current measured
1.63 A
1.60 A
–
input power measured
323 W
309 W
–
thermal dissipation
1103 BTU/hr
1054 BTU/hr
Input power frequency
50 to 60 Hz
50 to 60 Hz
Chassis
2U, 19" rack-mountable
Power supplies
Dual redundant, hot pluggable
Maximum disk drives
12 x 1 TB SATA II drives
Maximum net Capacity
~7000 GB (RAID-4 configuration)
DDR2 memory (System RAM)
1024 MB
Nonvolatile SDRAM (NVRAM)
256 MB - protects “in flight”
transactions for 3 days in the event of a
power loss.
Integrated I/O
2 Ethernet 10/100/1000 Copper
Remote management (via LAN)
Yes
Chassis
2U, 19" rack-mountable
Power supplies
Dual redundant, hot pluggable
Maximum disk drives
12 x 1 TB SATA II drives
Maximum net Capacity
~7000 GB (RAID-4 configuration)
DDR2 memory (System RAM)
4096 MB
Nonvolatile SDRAM (NVRAM)
256 MB - protects “in flight”
transactions for 3 days in the event of a
power loss.
Integrated I/O
4 Ethernet 10/100/1000 Copper
Remote management (via LAN)
Yes
Chassis
4U, 19" rack-mountable
Power supplies
Dual redundant, hot pluggable
Maximum disk drives
20 x 1 TB SATA II drives
Maximum net Capacity
~11 400 GB (RAID-DP configuration)
DDR2 memory (System RAM)
2048 MB
Содержание DSA-N2B40
Страница 1: ...DSDA Digital Storage Disk Arrays DSA N2B20 DSA N2B40 DSA N2B50 en Installation Guide ...
Страница 2: ......
Страница 37: ......