DSDA Digital Storage Disk Arrays
Monitoring and Maintenance | en
29
Bosch Sicherheitssysteme GmbH
Installation Guide
- | V2 | 2009.11
There are four LEDs on the power supply unit on the rear side of each shelf.
If either the
Fan LED
or the
Power LED
are lit
amber
, the power supply unit must be replaced.
At the front side of each disk drive, there are two LEDs.
–
If
no
LED is lit, the drive is not recognized. Reinsert the drive.
–
If one LED is lit
amber
, a fault is indicated. The drive must be replaced.
8.4
Software Update
NOTICE!
Only Bosch certified software can be used.
NOTICE!
To update the software, the system must reboot. During this process, no data can be written
to the system.
NOTICE!
If you are not using VRM, you need a program that functions as a Web server.
For example, you can use
AIDeX Mini-Webserver
which can be downloaded from
http://
www.aidex.de/software/webserver/
.