5.5
Alarm and relay connector
Figure 5.6
Alarm and relay connector pins
Alarm Input
–
AWG 26-16 max.(0.13-1.5 mm
2
); cut back 5 mm (0.2 in) of
insulation.
–
Impedence: Internal pull-up 10 kOhm to +5 VDC.
–
Input voltage range: -5 VDC minimum to 40 VDC maximum.
–
Input voltage treshold: low voltage 0.8 V maximum, high
voltage 2.4 V minimum.
–
Configurable as active low or active high.
Use the alarm input to connect external alarm devices such as
door contacts or sensors. A zero potential make or break
contact can be used as the actuator (use a bounce-free contact
system).
Relay output
–
Max. wire diameter AWG 22-28 for both stranded and
solid; cut back 5 mm (0.2 in) of insulation.
–
Output relay switching capability: Max voltage 30VAC or
+40 VDC. Max 0.5 A continuous, 10 VA.
–
Max. 42 V allowed between camera ground and each of the
relay pins.
Pin
Alarm socket
1
Alarm in 1
2
Alarm in 2
3
Relay out contact 1
4
Ground
5
Ground
6
Relay out contact 2
Alarm