DinionHD 720p IP Camera
Advanced Mode
| en
69
Bosch Security Systems
Installation and Operation Manual
AR18-10-B013 | v1.52 | 2011.06
9.4.11
Installer Menu
Synchronization
Select the
Synchronization
method for the camera:
–
Line lock
to lock to the power supply frequency;
–
Internal
for free running camera operation.
Ticker bar
Switches a ticker bar on the live image on or off.
Camera LED
Disable the
Camera LED
on the camera to switch it off.
Show test pattern
Select
On
to show a video test signal.
Pattern
Select the desired test pattern to help with installation and
fault-finding.
Main frequency
Select
50 Hz
or
60 Hz
as the main frequency for the camera.
Note:
Shutter times and frame rates are affected by the value
selected here.
Lens Wizard...
Click
Lens Wizard...
to open a separate window which can be
used to focus the camera lens.
To focus the lens on a particular area in the
Lens Wizard
window:
1.
Check the
Enable zoom
box.
2.
Use the mouse to adjust the size and position of the
shaded area in the preview window.
–
The main window zooms in on this area.
3.
Adjust the lens.
4.
Click
Reset
to return the shaded area to its default size
and position.