Dinion2X
Configuration | en
37
Bosch Security Systems
Installation Manual
AR18-08-B013 | v1.0 | 2009.03
5.6.3
Synchronization submenu
5.6.4
Alarm I/O submenu
Item
Selection
Description
Synchroniza-
tion
Internal
Line lock
HV lock,
Genlock,
Internal - for free running camera operation.
Line lock - to lock to the AC power supply
HV lock - locks the camera to the sync signal
supplied to the SYNC connector.
Genlock - locks the camera’s subcarrier to the
signal supplied to the SYNC connector.
Horizontal
phase
-25 . . 0 . . +25
Adjusts the horizontal phase offset.
Subphase
0, 2 . . . 358
Adjusts the subcarrier phase.
EXIT
Returns to Install menu.
Item
Selection
Description
Alarm input
None, high,
low
Select none to disable the alarm input. Select
active-high or active-low for the alarm input
connector.
Alarm action
None,
Mode 1 to 6,
Mono
Selects the operating mode of the camera
when the alarm input is active.
Содержание Dinion2X NBN-498
Страница 1: ...Dinion2X LTC0498 LTC0630 en Installation Manual ...
Страница 2: ......
Страница 10: ...10 en Introduction Dinion2X AR18 08 B013 v1 0 2009 03 Installation Manual Bosch Security Systems ...
Страница 12: ...12 en Installation Dinion2X AR18 08 B013 v1 0 2009 03 Installation Manual Bosch Security Systems ...
Страница 42: ...42 en Configuration Dinion2X AR18 08 B013 v1 0 2009 03 Installation Manual Bosch Security Systems ...
Страница 46: ...46 en Maintenance Dinion2X AR18 08 B013 v1 0 2009 03 Installation Manual Bosch Security Systems ...
Страница 52: ...52 en Technical Data Dinion2X AR18 08 B013 v1 0 2009 03 Installation Manual Bosch Security Systems ...
Страница 60: ...60 en Dinion2X AR18 08 B013 v1 0 2009 03 Installation Manual Bosch Security Systems ...
Страница 61: ......
Страница 62: ...Bosch Security Systems www boschsecurity com Bosch Security Systems 2009 ...