background image

4

In combination with an activated vapour 

extractor hood, room air is extracted from 

the kitchen and neighbouring rooms - a 

partial vacuum is produced if not enough 

fresh air is supplied. Toxic gases from the 

chimney or the extraction shaft are sucked 

back into the living space.

Adequate incoming air must therefore 

always be ensured.

An incoming/exhaust air wall box alone 

will not ensure compliance with the limit.

Safe operation is possible only when the 

partial vacuum in the place where the heat-

producing appliance is installed does not 

exceed 4 Pa (0.04 mbar). This can be 

achieved when the air needed for 

combustion is able to enter through 

openings that cannot be sealed, for 

example in doors, windows, incoming/

exhaust air wall boxes or by other technical 

means.

In any case, consult your responsible 

Master Chimney Sweep. He is able to 

assess the house's entire ventilation setup 

and will suggest the suitable ventilation 

measures to you.
Unrestricted operation is possible if the 

vapour extractor hood is operated 

exclusively in the circulating-air mode.

Risk of fire!

Grease deposits in the grease filter may 

catch fire.

Clean the grease filter at least every 

2 months. 

Never operate the appliance without the 

grease filter.

Risk of fire!

Grease deposits in the grease filter may 

catch fire. Never work with naked flames 

close to the appliance (e.g. flambéing). Do 

not install the appliance near a heat-

producing appliance for solid fuel (e.g. 

wood or coal) unless a closed, non-

removable cover is available. There must 

be no flying sparks.

Risk of fire!

Hot oil and fat can ignite very quickly. 

Never leave hot fat or oil unattended. 

Never use water to put out burning oil or 

fat. Switch off the hotplate. Extinguish 

flames carefully using a lid, fire blanket or 

something similar. 

Risk of fire!

When gas burners are in operation without 

any cookware placed on them, they can 

build up a lot of heat. A ventilation 

appliance installed above the cooker may 

become damaged or catch fire. Only 

operate the gas burners with cookware on 

them.

Risk of fire!

Operating several gas burners at the 

same time gives rise to a great deal of 

heat. A ventilation appliance installed 

above the cooker may become damaged 

or catch fire. Never operate two gas 

burners simultaneously on the highest 

flame for longer than 15 minutes. One 

large burner of more than 5 kW (wok) is 

equivalent to the power of two gas 

burners.

Risk of burns!

The accessible parts become very hot when 

in operation. Never touch hot parts. Keep 

children at a safe distance.

Risk of injury!

Components inside the appliance may 

have sharp edges. Wear protective gloves.

Risk of injury!

Items placed on the appliance may fall 

down. Do not place any objects on the 

appliance.

Risk of electric shock!

A defective appliance may cause electric 

shock. Never switch on a defective 

appliance. Unplug the appliance from the 

mains or switch off the circuit breaker in 

the fuse box. Contact the after-sales 

service.

Risk of electric shock!

Incorrect repairs are dangerous. Repairs 

may only be carried out and damaged 

power cables replaced by one of our 

trained after-sales technicians. If the 

appliance is defective, unplug the 

appliance from the mains or switch off the 

circuit breaker in the fuse box. Contact the 

after-sales service.

Risk of electric shock!

Do not use any high-pressure cleaners or 

steam cleaners, which can result in an 

electric shock.

Содержание DID068R59

Страница 1: ... en Instruction manual Extractor hood DID068R59 ...

Страница 2: ......

Страница 3: ... sea level This appliance may be used by children over the age of 8 years old and by persons with reduced physical sensory or mental capabilities or by persons with a lack of experience or knowledge if they are supervised or are instructed by a person responsible for their safety how to use the appliance safely and have understood the associated hazards Children must not play with on or around the...

Страница 4: ...uickly Never leave hot fat or oil unattended Never use water to put out burning oil or fat Switch off the hotplate Extinguish flames carefully using a lid fire blanket or something similar Risk of fire When gas burners are in operation without any cookware placed on them they can build up a lot of heat A ventilation appliance installed above the cooker may become damaged or catch fire Only operate...

Страница 5: ...g if you no longer require it Clean and if required replace the filter at regular intervals in order to increase the effectiveness of the ventilation system and to prevent the risk of fire Environmentally friendly disposal Dispose of packaging in an environmentally friendly manner Operating modes This appliance can be used in exhaust air mode or circulating air mode Exhaust air mode Note The exhau...

Страница 6: ...es back to fan level 2 Fan run on With fan run on the appliance switches off automatically after 10 minutes Press the y button Note The fan run on is only activatable in fan levels 1 3 Lighting The lighting can be switched on and off independently of the ventilation system Press the B button RGB function Press the P button repeatedly until the desired colour is set Note You can set the colour in t...

Страница 7: ...e holder for the metal mesh grease filters in the appliance using a damp cloth The metal mesh grease filters can be cleaned in the dishwasher or by hand By hand Note You can use a special grease solvent for stubborn dirt It can be ordered via the Online Shop Soak the metal mesh grease filters in a hot soapy solution Clean the filters with a brush and then rinse them thoroughly Leave the metal mesh...

Страница 8: ...evel to prevent fat from dripping out 5 Clean the appliance from the inside 6 Clean the metal grease filter and let it dry before re fitting Installing the metal mesh grease filter 1 Insert metal grease filter While doing this place your other hand under the metal grease filter 2 Fold up metal grease filter and engage the lock 3 Close the filter cover upwards Note Ensure that the filter cover lock...

Страница 9: ...be the result of operator error even during the warranty period Please find the contact data of all countries in the enclosed customer service list To book an engineer visit and product advice Rely on the professionalism of the manufacturer You can therefore be sure that the repair is carried out by trained service technicians who carry original spare parts for your appliances Fault Possible cause...

Страница 10: ...10 Accessories for circulated air mode not included in the delivery DSZ5300 DSZ5201 ...

Страница 11: ...11 ...

Страница 12: ...951201 9001021509 9001021509 Robert Bosch Hausgeräte GmbH Carl Wery Straße 34 81739 München Germany www bosch home com ...