en
Installation instructions
22
Risk of poisoning from flue gases being drawn back in.
▶
If an extractor hood with an open-flued heat production source
is installed, the power supply for the extractor hood must be
provided with a suitable safety switch.
Risk of poisoning from flue gases being drawn back in.
▶
Do not emit the exhaust air into a smoke or exhaust gas flue
that is in operation.
▶
Do not emit the exhaust air into a shaft that is used to ventilate
installation rooms for heat-producing appliances.
▶
If the exhaust air is to be conveyed into a smoke or exhaust gas
flue, you must obtain the consent of the heating engineer re-
sponsible.
WARNING ‒ Risk of suffocation!
Children may put packaging material over their heads or wrap
themselves up in it and suffocate.
▶
Keep packaging material away from children.
▶
Do not let children play with packaging material.
WARNING ‒ Risk of fire!
Grease deposits in the grease filter may catch fire.
▶
The specified safety clearances must be complied with in order
to prevent a build-up of heat.
▶
Observe the specifications for your cooking appliances. If the in-
stallation instructions for the cooking appliances specify a differ-
ent clearance, the larger of the two must always be provided
for. If gas hobs and electric hobs are operated together, the
largest specified clearance applies.
▶
The appliance must be installed with no more than one side dir-
ectly next to a high-sided unit or a wall. The distance between
the appliance and wall or high-sided unit must be at least
50 mm.
The grease deposits in the grease filter may catch fire.
▶
Never work with naked flames close to the appliance (e.g. flam-
béing).