en
Operating the appliance
6
1
Operating the appliance
Operating
the appl
iance
These instructions apply to several appliance variants. It
is possible that individual features are described which
do not apply to your appliance.
Note:
Switch on the extractor hood when you start
cooking and switch it off again several minutes after you
have finished cooking. This is the most effective way of
removing the kitchen fumes.
Control panel model 1
Control panel
Setting the fan
Switching on
Pull out the filter pull-out and press the
%
button. The
fan starts at setting
ƒ
.
Press the + or - button to change the fan strength.
Switching off
Press the
%
button. Slide the filter pull-out in.
Intensive setting
You can use the intensive setting if there is a large
build-up of odours and fumes/vapours.
Press the + button when the fan is at setting
„
.
The intensive boost setting
‚
is activated. Pressing the +
button again activates the intensive boost
ƒ
setting.
After approx. six minutes, the electronics automatically
reduce the fan to a lower setting . If you want to end the
intensive setting before the preset time expires, press
the - button until the required fan setting is reached.
Fan run-on time
If you slide in the filter pull-out, the run-on time will be
activated for as long as the extractor hood is operating.
After approx. 10 minutes, the fan switches off
automatically.
Lighting
The lighting can be switched on and off independently
of the fan.
Press the
B
button.
Setting the brightness
Press and hold the
B
button until the desired
brightness is reached.
Saturation display
When the metal mesh grease filters or the activated
carbon filter are saturated, a signal sounds for approx.
4 seconds after the fan is switched off.
In addition, the corresponding symbol appears in the
display:
■
Metal mesh grease filter:
#
■
Activated carbon filter:
’
#
If you have not yet done so, the metal mesh grease
filters should be cleaned or the activated carbon filter
changed now.
For instructions on how to clean the metal mesh grease
filters, please refer to the section Cleaning and
maintenance.
While the saturation displays are flashing, they can be
reset. To do this, press the – button.
Switching over the display for circulating-air mode
For circulating-air mode, the electronic control display
must be switched over accordingly:
■
The extractor hood must be connected and switched
off.
■
Press the
%
and - button at the same time until the
™
#
display for starter sets for circulating-air mode or
’
#
display for CleanAir circulating air modules
lights up.
■
Repeatedly press the button combination to switch
the electronic control display back to exhaust air
mode (
#
display).
Audible signal
Switching on the acoustic signal
When the fan is switched off, press the
%
and +
buttons at the same time for approx. three seconds. An
acknowledgement signal sounds.
Switching off the acoustic signal
Repeat the "Switching on the acoustic signal" process.
Explanation
%
Fan on/off
-
Reduce the fan settings/fan run-on time
+
Increase the fan settings/intensive setting 1, 2
B
Light on/off/dimming
ERRVW
Содержание DFS097E50A
Страница 1: ... en Instructions for installation and use Extractor hood ...
Страница 18: ...en Installation 18 ...
Страница 19: ...Installation en 19 ...