8.3.2 Connecting base station-extension card
The connection of the base stations to the BS 8-15 connector of the extension card
(see figure 8.3) can be done in two different ways. One way is to solder the 25 pole male
sub D connector to the base station cables (see
1.
), the other way is buying a BS-DCU
connection cable LBB 6721/02 (see
2.
).
1.
Soldering the wires to a 25-pole male sub D connector according the pin
configuration in Table 8.1 and plug the connector on the BS 8-15 connector of the
extension card (see figure 8.3).
2.
Connect the optional BS-DCU connection cable to the BS 8-15 connector of the
extension card (see figure 8.3) and the wires via a terminal strip, located near by a
PABX, to the base stations (see figure 8.5). For wiring of the BS-DCU connection
cable LBB 6721/02 see Table 8.2.
CHAPTER 8
Installation Instructions
DECT6000
27
9922
141
80271
03-07
en
Pin
Signal
Line
Pin
Signal
Line
1
a
8
5
a
12
14
b
18
b
2
a
9
6
a
13
15
b
19
b
3
a
10
7
a
14
16
b
20
b
4
a
11
8
a
15
17
b
21
b
9…13
Not connected
22…25
Not connected
Table 8.1 Base station to DCU connector
Pin
Signal
Wire colour
Line
Pin
Signal
Wire colour
Line
1
a
white/blue
8
5
a
white/grey
12
14
b
blue/white
18
b
grey/white
2
a
white/orange
9
6
a
red/blue
13
15
b
orange/white
19
b
blue/red
3
a
white/green
10
7
a
red/orange
14
16
b
green/white
20
b
orange/red
4
a
white/brown
11
8
a
red/green
15
17
b
brown/white
21
b
green/red
9...13
Not connected
22...25
Not connected
Table 8.2 Connections of the BS-DCU connection cable LBB 6721/02