background image

DCN Next Generation Release Notes

 

en | 11 

                                                   

 

Bosch Security Systems| 2014-10-31 

Product/function 

Problem 

Solution 

DCN-SWWA 

Does not work with 
DCN-SW 

DCN-SWWA 1.1.1 requires DCN-SW 4.2x or later 

DCN-SWWA 1.0.1 requires DCN-SW 4.1x 

DCN-SWWA 

Webcast will stop 
after 12 hours. 

Maximum webcast length of a webcast is 12 hours. It 

will stop automatically. 

DCN-SWWA 

No audio on SDI input 
box 

With setup, please note if there is no audio, resetting 

the Audio to SDI box most of the time will solve the 

problem. 

DCN-SWWA 

Opinion Poll and 
Multiple Choice 
information from 
DCN-SWSMD is not 
supported. 

none 

DCN-SWWAEC 

Slave languages not 
added after using 
Refresh function. 

Refresh webcast will only effect PowerPoint slides. 

Load webcast will add the languages 

DCN-SWWAEC 

Webcast will not start 
on slave PC’s. 

Close the publisher on slave PC’s before starting a 

new webcast. 

Not all text is 

shown on 

Webcasting player 

For security reasons, 
all text between the 
signs ‘<’and ‘>’ is 
removed and currently 
not shown on the 
webcasting player 
website. 

Do not use the “<” and “>” characters in DCN-SW 

(e.g. meeting information, session information, voting 

information, delegate names) or Webcast Planner 

Website. 

Wireless system in 

combination with 

Integrus 

No audio on DCN 
wireless units when 
powering up DCN-
CCU2 and Integrus 
transmitter 
simultaneous. 

First power up the DCN-CCU2. After it is powered up, 

power up the Integrus transmitter. 

Not able to 

download DCN-

CCU2 firmware 

DCN-DLT is not able 

to download the 

firmware of the CCU 

Check if the DCN-SW server is not running: 

1.

 

Exit the DCN-DLT program 

2.

 

Check if the DCN-CCU2 does not report PC 

on it’s display. If it does Stop the DCN-SW 

server via Start\ <Search programs and files> 

SERVICES. Services (local). And check if PC 

disappears. 

3.

 

Start DCN-DLT (PC will now re-appear in the 

CCU2 screen, but that is correct) and start 

the download. 

If the download still fails, do the following: 

1.

 

Power off and open the DCN-CCU2 

2.

 

Set switch 8 of S600 to ON and power on the 

CCU. 

3.

 

Download the CCU using the DCN-DLT. 

4.

 

After a succesfull download, power off the 

CCU, set switch 8 of S600 to OFF again and 

power on the CCU. 

HD Conference 

Dome 

The HD Conference 

Dome will show an 

incorrect name & 

picture combination if 

a new pre-position is 

asked before it 

reaches it’s pre-

position. 

Do not activate another microphone until the HD 

Conference Dome has reached it’s pre-position. 

DCN-UPTK 

The type of the unit 

connected to the 

UPTK is not valid. 

This notification can occur when the DCN-UPTK unit 

is used extensively. Please replace the connection 

cable. 

Содержание DCN Next Generation 4.41

Страница 1: ...DCN Next Generation 4 41 Release Notes en Release Notes ...

Страница 2: ...his release Contains The following versions are part of this release Product version DCN SW 4 41 DCN SWSMV 4 40 DCN SWSACC 4 40 DCN SWWA 1 11 DCN DLT CCU2 4 41 DCN CCU2 4 41 HdCameraControl 4 40 DCN DLT CCU NCO 3 10 DCN CCU 3 10 2 Improved and added Functionality Release Release Date Release Comments 4 41 2014 11 02 New functionality and improvements Improved DCN wireless firmware to make it more ...

Страница 3: ...port for HdCameraControl Added Crystal Reports installer to Tools directory This needs to be installed to print the voting reports from DCN SWSMV Note Windows Vista is no longer supported for DCN SW DCN SWSMV DCN SWSACC HdCameraControl 4 30 2014 01 31 New functionality and improvements DcnHdCameraControl added second video switcher Kramer MV 6 DcnHdCameraControl made screen line configurable DcnHd...

Страница 4: ...nd set System ID for slave CCU s to Open Interface Response list length increased from 5 to max 25 and made configurable on CCU and via DCN SW Number of Open Microphones NOM increased from 4 to 25 Number of seats which can be added to the Notebook increased from 15 to 25 Increased Operator Application target size Added group speech timers to DCN SWSMD and DcnSmdDemonstrator application Added show ...

Страница 5: ...n added Only English User interface Only one audio channel language Fixes DCN SWSMD information regarding microphone on off DCN SWSMD information empty when session name and description are identical Stopping an Operator control session does not clear request list DCN MR wave form and audio sometimes not in sync DCN SW not all GUI texts fit DCN SWSMV Reset microphone sensitivity ALL MICROPHONES DC...

Страница 6: ... Product Hw FPGA SW FW DCN CCU2 na na 4 4x DCN CCU 1 07 3 1x DCN CCU in multi CCU mode 5 0 2 17 DCN NCO LBB 4120 00 Interpreter desk 1 2 Toggle in DCN IDESK 1 40 xxxx The following applications are compatible with this release Product Hw FPGA SW FW DCN SW 4 00 3959 4 40 4 40 DCN SWSMV 4 40 DCN SWSACC 4 40 DCN MR 2 0 Download and License Tool 4 40 DCN SWWA 1 10 HdCameraControl 4 40 Optical devices ...

Страница 7: ...cted beeps on delegate loudspeaker fixed DCN CCUB FPGA HW Fixes 1 22 1 0 Noise or no audio on delegate loudspeaker 1 09 1 0 Noise on delegate loudspeaker 1 08 1 0 Unexpected beeps on delegate loudspeaker DCN CONxx range FPGA HW Fixes Additions 1 17 hw1 12 1 0 Address might be lost after system restart 1 14 hw1 10 1 0 11Khz noise SW 1 10 xxxx hw1 13 1 0 CRC check added for ID cards DCN DDI FPGA HW ...

Страница 8: ...2014 10 31 FPGA HW Fixes Additions 02 03 1 0 The display might show unexpected characters 02 02 1 0 Improved stability when used in combination with the DCN system 02 01 1 0 Improved stability when used in combination with the DCN system 02 00 1 0 Initial version ...

Страница 9: ... the Tools directory of the DVD 6 Trouble Shootings and known issues This trouble shootings and known issues are in addition to chapter 2 and to the trouble shooting chapter in the user manuals Product function Problem Solution DCN SW Configuration Application In rare occasions it can happen that the application closes unintended Restart the DCN SW Configuration Application DCN SW rinting individu...

Страница 10: ...tains all settings like seats meetings synoptic layouts etc will always be removed during a downgrade DCN SW Unexpected behaviour or no reaction of DCN SW Due to Windows Automatic Updates some critical components like SQL Server Express might be temporarily not available for DCN SW Do not set Automatic Updates to Automatic or restart your system after the Automatic updates have been installed DCN ...

Страница 11: ...reless system in combination with Integrus No audio on DCN wireless units when powering up DCN CCU2 and Integrus transmitter simultaneous First power up the DCN CCU2 After it is powered up power up the Integrus transmitter Not able to download DCN CCU2 firmware DCN DLT is not able to download the firmware of the CCU Check if the DCN SW server is not running 1 Exit the DCN DLT program 2 Check if th...

Страница 12: ...e Meeting Recorder ini file with notepad it is located here C Users USER NAME AppData Roaming Meeting Recorder if the user name is administrator the path will be C Users Administrator AppData Roaming Meeting Recorder 2 Find the variable NCO Ip x x x x where x x x x is the IP address of DCN SW server and below that line Create a line DCO Ip x x x x where x x x x is the IP address of the DCN SW serv...

Страница 13: ...with the next command line FTP with the command ftp n s dcn nco txt x x x x Where x x x x is the IP address of the NCO 8 Switch off the NCO and set the dipswitches all to off 9 Switch on the NCO 10 Start the Download and License Tool and start a NCO download DCN CCU DCN NCO Local floor muted after download of NCO or CCU Switch off and on the CCU or NCO DCN NCO DCN CCU INT TX04 08 16 32 Unexpected ...

Страница 14: ...to the remaining CCU s is shortly disrupted for 1 to 2 seconds DCN CCU Loss of settings after reboot of NCO in a Multi CCU system In case the Network Controller NCO in a Multi CCU system is rebooted the settings and configurations changed during the past 30 seconds can be lost When configuring interpreter desks wait minimum 30 seconds before reboot the NCO LBB 4402 00 LBB 4404 00 PRS 4DEX4 Input r...

Отзывы: