DCN Next Generation Release Notes
en | 12
Bosch Security Systems| 2014-10-31
Product/function
Problem
Solution
DCN-CCU(B)2
Error relays activated
upon system reset or
firmware download.
During a firmware download or system reset, the
system is not in normal operation and thus the error
relays can be active.
DCN-CONFF and
DCN-CONCM
DNPV answers in
voting are not visible
in the Concentus
screen when a voting
timer is activated.
Use a hall display or disable the voting timer.
DCN-SWSACC
and Allegiant
Double screenlines
are still visible on
audience screens
after switching to
single screenlines.
Restart the Allegiant.
DCN-SWSACC
Upload does not work
anymore.
Restart the DCN-CCU or DCN-NCO.
DCN-MR
DCN-MR does not
connect to DCN-SW
when installed on
another PC
1.
Open the Meeting Recorder.ini file with notepad
it is located here: C:\Users\[USER
NAME]\AppData\Roaming\Meeting Recorder
if the user name is administrator, the path will
be: C:\Users\
Administrator\AppData\Roaming\Meeting
Recorder
2.
Find the variable NCO Ip=x.x.x.x (where x.x.x.x is
the IP address of DCN SW server) and below that
line;
Create a line DCO Ip=x.x.x.x (where x.x.x.x is the
IP address of the DCN SW server)
NCO Port=20000
NCO Ip=10.120.22.230
DCO Ip=10.120.22.230
CCU Ip=192.168.1.1
3.
Save the Meeting Recorder.ini file
DCN-MR
Windows audio
playback is lost after
installation DCN-MR
1.3. in windows XP.
Replace files msacm32.drv, msadp32.acm and
imaadp32.acm in the windows system32 folder.
Multi CCU systems System reaction is
(very) slow after
system startup.
The system might become (very) slow when in a multi
CCU system only the NCO is switched off and the
rest of the system stays switched on.
To prevent this problem:
Shutdown all optical devices in the Multi-CCU system.