![Bosch DAS 3000 S20 Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/bosch/das-3000-s20/das-3000-s20_original-instructions-manual_50687012.webp)
1 689 989 485 | 2020-08-01
Robert Bosch GmbH
6. Attach the indicator bar to the positioning bars at
1.50 m.
7. Use the spirit level in the indicator bar to check
whether the left and right positioning bars are
aligned properly.
— If the spirit level shows an inclination, adjust the
left and right positioning bars precisely.
---
5.2
Attaching the calibration board in
vertical positions A, B or C
The mounting adapters are used for attaching all
calibration boards CTA 3xx-x to the
DAS 3000 S20.
---
1. Mount the mounting adapter
(1)
at vertical position
A, B or C.
2. Make sure the mounting adapter correctly engages
with the mounting pins
(3)
by the mounting guides
(2)
.
3. Use the knurled screw
(4)
to hand-tighten the
mounting adapter.
1
22
33
4
33
4
4712005-23_shd
(1) Mounting adapter
(2) Mounting guides
(3) Mounting pin
(4) Knurled screw
CAUTION – Pinch point hazard when positioning the
calibration board.
4. Do not place fingers or hands between the mounting
adapter
(1)
and the bottom edge
(2)
of the calibra‐
tion board.
5. Place the bottom edge of the calibration board
(2)
in
the mounting adapter
(1)
on the positioning unit
(3)
.
1
2
3
4712005-24_shd
(1) Mounting adapter
(2) Bottom edge of calibration board
(3) Positioning unit
6. Push calibration board retainer Z
(1)
onto the top
edge
(3)
of the calibration board in such a way that
the recess in calibration board retainer Z secures the
calibration board.
7. Use the knurled screw
(2)
to hand-tighten calibra‐
tion board retainer Z.
The calibration board is now secured and fixed in
place.
4712005-25_shd
1 2
3
4
(1) Calibration board retainer Z
(2) Top edge of calibration board
(3) Positioning unit
8. Make sure that the arrow and marking
(2)
on the
bottom edge of the calibration board align with the
mounting adapters
(1)
.
The calibration board is centered relative to the
DAS 3000 S20.
1
22
1
22
4712005-26_shd
(1) Mounting adapter
(2) Arrow and mark on calibration board for centering
---
en | 28 | DAS 3000 S20