Содержание D9210C

Страница 1: ...Access Control Interface Module D9210C en Program Entry Guide ...

Страница 2: ......

Страница 3: ...Systems Inc Program Entry Guide F 01U 201 526 02 2011 10 Table of Contents 1 Trademarks 4 2 Door Profile 5 3 Strike Profile 9 4 Event Profile 12 4 1 Notes 14 5 Program Record Sheets 15 5 1 Profiles 16 5 1 1 Door Profiles 16 5 1 2 Strike Profiles 16 5 1 3 Event Profiles 16 ...

Страница 4: ...categories and sections of the program are shown in italic capital letters For a more complete understanding of the panel and the D9210C Access Control Interface read the following in addition to this program entry guide D9210C Operation and Installation Guide P N F01U215244 Security System Owner s Manual Security System User Guide Other Lettering Conventions used in this document D6600 Security R...

Страница 5: ... to the door controller to which the reader will allow access Blank Door controller will not function Enter the Command Center number CC which determines the scope of the user ID s disarming rights Areas will disarm on the basis of this Command Center s scope and the Authority Level of the user Door Default 1 Selections 1 8 NOTICE The D9412 Family supports 8 doors the D7412 Family supports 2 doors...

Страница 6: ...ereby having one interlock point prevent multiple controllers from activating 1 127 129 247 The point number assigned to this door Points 128 and 248 are reserved by the panel for internal use Blank There is no point number assigned to this door D Door Point Default Blank Selections Blank 1 127 129 247 NOTICE Door Points must be programmed as Perimeter Points If a 24 hour point type is required fo...

Страница 7: ...doors with this prompt programmed YES when a Fire Alarm occurs in any area Relays that are activated by Fire Unlock can only be returned to normal through the Command Center using the Door Control function Yes Relay will activate and shunt will be applied for the door contact automatically upon a Fire Alarm No Door will remain in its current mode upon a Fire Alarm Use this program item to determin...

Страница 8: ...ram Entry Guide Bosch Security Systems Inc Yes The area will disarm only after the door has been opened for a user with a valid disarm level No The area will disarm whether or not the door has been opened as soon as a user with a valid disarm level has presented a valid token card ...

Страница 9: ... programmed for this door 1 240 The strike will activate for the amount of time programmed Enter the amount of time that the door point will be shunted to allow a user to open the door without causing the point to go into Trouble Alarm or a faulted condition Blank TShunt Time is not programmed for this door 1 240 The shunt will activate for the amount of time programmed Enter the amount of time th...

Страница 10: ...rogrammed strike time whether door is opened or closed TO REDUCE FALSE ALARMS We recommend that you maintain this programming item as defaulted YES This will help prevent the door from bouncing open and causing a false alarm Use this program item to disable the strike but still activate the programmed shunt time upon a Request to Enter an area D Extend Time Default 10 Selections Blank 1 30 seconds...

Страница 11: ... time upon a Request to Exit an area Yes Programmed shunt time will activate so door can be manually opened No Request to Exit REX automatically activates the programmed strike and shunt time NOTICE Use this parameter when a user can open a door manually without relying on a token card to activate the strike such as with a push bar NOTICE When RTE Shunt Only is Yes Request To Enter events are not ...

Страница 12: ...or armed state changes that hold a door open Request to enter exit RTE REX Yes Access events from this door controller will be sent to the panel for processing No Access events from this door controller will not be sent to the panel for processing This program item determines if No Entry events are sent to the panel for processing memory printing and remote reporting A No Entry event may be caused...

Страница 13: ...or controller is not sent to the panel for processing This program item determines if Request to Exit REX events are sent to the panel for processing memory printing and remote reporting Yes DOOR REQUEST TO EXIT event from this door controller is sent to the panel for processing No A DOOR REQUEST TO EXIT event from this door controller is not sent to the panel for processing D Enter Request Defaul...

Страница 14: ...14 en Event Profile Access Control Interface Module F 01U 201 526 02 2011 10 Program Entry Guide Bosch Security Systems Inc 4 1 Notes ...

Страница 15: ...s section are the Program Record Sheets used to document the configuration at a customer site Please feel free to de attach this section for your records Summary account information Subscriber name Date Address City State Zip Premises phone Installer name Door Point Point Text Location 1 2 3 4 5 6 7 8 Door s 3 through 8 for D9412 Family only Control Communicator Location ...

Страница 16: ...ilable for the D9412 Family only Door 1 Door 2 Door 3 Door 4 Door 5 Door 6 Door 7 Door 8 Strike Time 1 240 sec 10 10 10 10 10 10 10 10 Shunt Time blank 1 240 sec 10 10 10 10 10 10 10 10 Buzz Time blank 1 247 sec 2 2 2 2 2 2 2 2 Extend Time blank 1 30 10 10 10 10 10 10 10 10 Deactivate On Open Yes No Yes No Yes No Yes No Yes No Yes No Yes No Yes No RTE Shunt Only Yes No Yes No Yes No Yes No Yes No ...

Страница 17: ......

Страница 18: ...Bosch Security Systems Inc 130 Perinton Parkway Fairport NY 14450 United States www boschsecurity com Bosch Security Systems Inc 2011 ...