Access Control Interface Module
Strike Profile | en
11
Bosch Security Systems, Inc.
Program Entry Guide
F.01U.201.526 | 02 | 2011.10
Yes
Programmed shunt time will activate so door can be manually opened.
No
Request to Enter [RTE] automatically activates the programmed strike and shunt time.
Use this program item to disable the strike, but still activate the programmed shunt time upon
a Request to Exit an area.
Yes
Programmed shunt time will activate so door can be manually opened.
No
Request to Exit [REX] automatically activates the programmed strike and shunt time.
NOTICE!
Use this parameter when a user can open a door manually without relying on a token/card to
activate the strike (such as with a “push bar”).
NOTICE!
When RTE Shunt Only is [Yes] Request To Enter events are not logged, reported, or printed.
D# REXShunt Only?
Default:
No
Selections:
Yes or No
NOTICE!
When REX Shunt Only is [Yes] Request To Exit events are not logged, reported, or printed.