D2212B/D2212BE Operation and Installation Guide
D2212B/D2212BE
Page 11
© 2002 Bosch Security Systems
39934E
2.0
Overview
2.1
Specifications
Table 3: D2212B/D2212BE Specifications
Overview
Primary
D2412U: 16.5 VAC 40 VA 2 plug-in transformer (D1640)
D2412UE: 16.5 VAC 25VA 2 plug-in transformer (D1625)
Voltage input
(Power Supply)
Secondary
12 VDC 7.0 Ah sealed lead acid rechargeable battery
D2212B
1.0 A maximum at 10.2 VDC to 13.9 VDC for
devices powered at the Aux+ terminal (140 mA
for Fire and combined Fire/Burglary systems)
Auxiliary
Power Output
D2212BE
500 mA maximum at 10.2 VDC to 13.9 VDC for
devices powered at the Aux+ terminal (140 mA
for Fire and combined Fire/Burglary systems)
Alarm Power
Output
1.35 A maximum at 10.2 VDC to 13.9 VDC output. Output
may be steady or pulsed depending on programming.
Power Outputs
Fire and Fire/
Burglary
Systems
To comply with UL 985 Listing standards for household fire
alarm systems (effective March 1, 1989), the total combined
continuous and alarm current draw for the system during
alarm conditions must be limited to 860 mA provided by the
primary power supply (rectified AC).
Minimum
10.2 VDC
Operating
Voltage
Maximum
13.9 VDC
Telephone Connection
RJ31X or RJ38X jack interfaced with D164 phone cord
Environmental
Temperature
+32°F to +122°F (0° to +50°C)
Relative
Humidity
5 to 85% @ +86°F (+30°C) non-condensing