CLIMATE 5000 RAC SINGLE SPLIT (R32) – 6720894076 (2019/08)
39
Troubleshooting
5.4
Quick Maintenance by Error Code
Following table shows the error codes in combination with possible
component which may cause the failure.
Related components can be checked first for a quick diagnose.
Component
Error Code
E0
E1
E3
E4
E5
E7
EC
F0
F1
Indoor PCB
✓
✓
✓
✓
✓
✓
✓
✗
✗
Outdoor PCB
✗
✓
✗
✗
✗
✗
✗
✓
✓
Reactor
✗
✓
✗
✗
✗
✗
✗
✗
✗
Indoor fan motor
✗
✗
✓
✗
✗
✗
✗
✗
✗
Outdoor fan motor
✗
✗
✗
✗
✗
✗
✗
✗
✗
Temperature sensor
✗
✗
✗
✓
✓
✗
✓
✗
✓
T2 Sensor
✗
✗
✗
✗
✗
✗
✓
✗
✗
Additional refrigerant
✗
✗
✗
✗
✗
✗
✗
✗
✗
Compressor
✗
✗
✗
✗
✗
✗
✗
✓
✗
IPM board
✗
✗
✗
✗
✗
✗
✗
✗
✗
Outdoor unit
✗
✗
✗
✗
✗
✗
✗
✓
✗
Display board
✗
✗
✗
✗
✗
✓
✗
✗
✗
Table 12.
Component
Error Code
F2
F3
F4
F5
P0
P1
P2
P4
Indoor PCB
✗
✗
✗
✗
✗
✗
✗
✗
Outdoor PCB
✓
✓
✓
✓
✓
✓
✓
✓
Reactor
✗
✗
✗
✗
✗
✓
✗
✗
Indoor fan motor
✗
✗
✗
✗
✗
✗
✗
✗
Outdoor fan motor
✗
✗
✗
✓
✗
✗
✗
✗
Temperature sensor
✓
✓
✗
✗
✗
✗
✗
✗
T2 Sensor
✗
✗
✗
✗
✗
✗
✗
✗
Additional refrigerant
✗
✗
✗
✗
✗
✗
✗
✗
Compressor
✗
✗
✗
✗
✓
✗
✗
✓
IPM board
✗
✗
✗
✗
✓
✓
✗
✓
Outdoor unit
✗
✗
✗
✗
✗
✗
✗
✗
Table 13.