56
CLIMATE 5000 RAC SINGLE SPLIT (R32) – 6720894076 (2019/08)
Troubleshooting
5.5.13 P4 (Inverter compressor drive error diagnosis and solution)
Description:
An abnormal inverter compressor drive is detected by a special detection circuit, including communication signal detection, voltage
detection, compressor rotation speed signal detection and so on.
Possible defects:
•
Wiring mistake
•
IPM malfunction
•
Faulty outdoor fan assembly
•
Compressor malfunction
•
Faulty outdoor PCB
Troubleshooting and repair:
YES
YES
YES
YES
NO
NO
NO
NO
Ensure proper connections or replace the
wires and connectors.
Replace the compressor.
Replace the outdoor PCB.
Replace the IPM board
or the outdoor PCB.
Please refer to “Fan Speed
Malfunction”
Does it function
properly?
Does it function
properly?
Are they within
acceptable ranges?
Is it improperly wired?
Check the wiring between the PCB
and compressor.
Check the outdoor fan and the
outdoor unit ventilation.
Check the compressor resistance
values.
Check the IPM.
Содержание Climate 5000
Страница 1: ...6720894076 2019 08 GB CLIMATE 5000 RAC SINGLE SPLIT R32 SERVICE MANUAL ...
Страница 61: ......
Страница 62: ......
Страница 63: ......
Страница 64: ...Bosch Thermotechnik GmbH Junkersstrasse 20 24 D 73249 Wernau www bosch thermotechnology com ...