Climate 5000 SCI – 6720887422 (2019/07)
21
Wiring
CAUTION
•
If there is no change in the ventilation paths after airflow adjust-
ment, be sure to reset automatic airflow adjustment.
•
If there is no change to ventilation paths after airflow adjustment,
contact qualified personnel, especially if this occurs after testing
the outdoor unit or if the unit has been moved to a different location.
•
Do not use automatic airflow adjustment with remote control if you
are using booster fans, outdoor air processing unit, or an HRV via
duct.
•
If the ventilation paths have been changed, reset airflow automatic
adjustment as described from step 3 onwards.
8.3
Power Specifications
NOTE:
Electric auxiliary heating type circuit breaker/fuse need to add more
than 10 A.
Inverter Type A/C Power Specifications
MODEL (Btu/h)
≤
18K
19K~24K
25K~36K
≤
36K
37K~60K
POWER
(indoor)
PHASE
1 phase
1 phase
1 phase
1 phase
1 phase
VOLT
220-240 V
220-240 V
220-240 V
220-240 V
220-240 V
CIRCUIT BREAKER/FUSE(A)
15/10
15/10
15/10
15/10
15/10
POWER
(outdoor)
PHASE
1 phase
1 phase
1 phase
3 phase
3 phase
VOLT
208-240 V
208-240 V
208-240 V
380-415 V
380-415 V
CIRCUIT BREAKER/FUSE(A)
25/20
25/20
40/30
25/20
32/25
Table 14.