Problem solving
Primary fan rotation too low in
operation.
1. Disconnect power supply cord and check wire connection on
back side of fan and the connectors on the control board, see
Fig.
84
,
page 65
.
2. Check supply voltage. It must be 120VAC and properly
grounded.
3. Check venting specifications are met. Long vent lengths,
venting with more than three elbows, blocked vent or combination
venting may cause this failure.
4. Ensure intake and exhaust terminations maintain the required
clearances stated in the manual. Cross contamination between
intake and exhaust may cause the fan to alter its rotational speed.
5. Check gas pressure. Low gas pressure may cause the fan to
change its speed to meet desired temperature.
6. Possible defective control unit call Bosch Water Heating for
further instructions.
No rotational speed sensor signal
from primary fan.
1. Disconnect power supply cord and check wire connections on
back side of fan and the two connectors on the control board, see
Fig. 84
,
page 65
.
2. Check supply voltage. It must be 120VAC and properly
grounded.
3. Possible defective component in fan or defective control unit
call Bosch Water Heating for further instructions.
(Flashing)
Water flow signal over specified
maximum value.
Water flow > 10 gallon/min.
(Status message).
1. Disconnect power supply cord and check wire connections on
water valve and the two connectors on the control board, see
Fig.
84
,
page 65
.
2. Excessive water pressure and flow. Ensure water pressure is
less than 150psi and flow rate is below 10 gallons per minute.
Over-temperature detected by
outlet temperature sensor.
Temperature > 185°F
1. Check that the sensor is firmly attached to the horizontal section
of the hot water pipe, see
Fig. 83
,
page 64
.
2. Check red wire connections at hot water temperature sensor.
Clean terminals with an eraser. If badly corroded, replace sensor
and wire harness.
3. In areas where water has a high mineral content, periodic
descaling may be necessary. See chapter
6.3
,
page 42
for
directions.
4. Check sensor (ref.
page 53, chapter 9).
Cold water temperature sensor
fault.
1. Check connector on wires coming from top of watervalve for a
secure connection. See
Fig. 77
,
page 57
.
2. Sensor may trip if water temperature drops below 36°F (2
°
C).
Protect heater from freezing conditions as any damage due to
freezing conditions is not covered under warranty.
3. Check sensor (ref.
page 54, chapter 10).
Display
Cause
Solution
Table 29
* By installer or service technician only.
Содержание C1050ES
Страница 56: ...6 720 646 812 56 Functional scheme 11 Functional scheme Fig 76 Functional scheme ...
Страница 58: ...6 720 646 812 58 Interior components diagram and parts list Fig 78 Appliance overview ...
Страница 69: ...6 720 646 812 Notes 69 15 Notes ...
Страница 70: ...6 720 646 812 70 Notes ...
Страница 71: ...6 720 646 812 Notes 71 ...