18.3 Fitted units
This appliance is only intended to be fully fitted in a kit-
chen. It is not intended to be used as a tabletop appli-
ance or within a cupboard.
The installation cabinet must not have a back panel be-
hind the appliance. The minimum installation height is
850 mm.
Ventilation slots and intakes must not be covered.
18.4 Electrical connection
In order to safely connect the appliance to the elec-
trical system, follow these instructions.
¡
The appliance corresponds to protection class I and
must only be operated with a protective earth con-
nection.
¡
The fuse protection must correspond to the power
rating specified on the appliance's rating plate and
to the local regulations.
¡
The appliance must be disconnected from the
power supply whenever installation work is being
carried out.
¡
The appliance must only be connected using the
power cable provided.
¡
The power cable must be plugged in at the rear of
the appliance. A 3 m power cable can be obtained
from customer service.
¡
The power cable must only be replaced with a cable
from the original manufacturer. This is available from
customer service.
Connecting the appliance to the electricity
supply
Note:
The appliance must only be connected to a pro-
tective contact socket that has been correctly installed.
1.
Insert the non-heating appliance plug of the power
cable into the appliance.
Check that the non-heating appliance plug is inser-
ted properly.
2.
Insert the mains plug of the appliance into a nearby
socket.
When the appliance is installed, the mains plug of
the power cable must be freely accessible. If free
access to the mains plug is impossible, an all-pole
isolating switch must be integrated into the perman-
ent electrical installation in accordance with the in-
stallation regulations.
18.5 Installation in an upper cabinet
Observe the installation dimensions and the safety
clearances in a tall unit.
Do not fit the appliance too high up; it must be pos-
sible for accessories to be removed easily.
Remove the feet.
18.6 Installation in a tall unit