4. Product description
4.1
Intended use
The networkable exhaust gas analyzer BEA 750 permits
user-friendly performance of exhaust emissions tests on
gasoline vehicles.
The range of test specimens includes the entire
spectrum of gasoline road vehicles on which emission
measurements have to be taken during workshop
inspections, both to comply with legal requirements
and for the purposes of localizing and rectifying faults.
BEA-PC software is installed on the BEA 750.
!
The BEA 750 must be operated only in enclosed
workshop areas. Protect the BEA 750 against
moisture. The BEA 750 must not be exposed to
sources of heat (e.g. direct sunlight) and excessive
soiling.
4.2
Scope of delivery
i
The scope of delivery depends on the product variant
ordered as well as the special accessories ordered,
and can deviate from the following list.
Designation
Part number
BEA 065, stylus (with cord)
–
Thermal printer paper (5x)
1 681 420 028
Coarse filter
1 687 432 005
Remote control
–
Hose (8 m) and exhaust gas sampling probe
(gasoline) with attached hose (30 cm) and
leak test hose fitting
1 680 703 043
1 680 790 049
PVC hose (5x1,5) for BEA 065 (2x 1440 mm)
–
Operating instructions
1 689 979 922
1 689 989 338
1 689 989 339
4.3
Product description
The BEA 750 consists of a touchscreen, thermal printer,
computer board with temperature, engine speed and
exhaust gas measurement functions. Communication
between the BEA 750 and, for instance, the BEA 070 is
established via Bluetooth or a USB connection.
459969-0
31_K
o
1
2
3
4
6
7
8
9
5
10
Fig. 1:
BEA 750 Front panel
1 Shelf
2 Sensor bracket
3 Touchscreen
4 Thermal printer
5 Printer cover
6 Remote control receiver
7 LED (see sec. 4.3.2)
8 Paper feed key
9 Power key
10 Built-in WLAN module (circuit board with antenna)
459969-073_Rf
1
2
3
4
5
6
7
8
9
0
10
11
12
13
GF 2
GF 3
AF I
O2
N0
cal
Fig. 2:
Rear view of BEA 750
1 Coarse filter GF2
2 Coarse filter GF3
3 Exhaust gas measurement inlet
4 Active carbon filter AF1
5 O
2
sensor
6 Measurement gas outlet
7 Condensate port
8 Calibrating gas inlet
9 NO sensor (special accessory)
10 On/Off switch
11 Voltage supply connection
12 Computer board interface (see sec. 4.3.1)
13 USB interface for the Bluetooth USB adapter