10/54 Safety instructions | Automax 100 | Basic module TS-AC B1-M2-1X
Bosch Rexroth AG | 04.2021 | DOK-SUPPL*-TS-AC B1-M2-ITRS-EN-P
Symbol
Description
Disconnect mains plug (before opening)
Registration number: M006
2.9
Safety equipment
To protect people, the product is equipped with the following safety equipment:
Contact-protected safety sockets
Main switch
Internal fuse protection of the supply voltage for extension modules
The main switch button disconnects the product on all poles from the connected supply
voltage.
Fuse protection of voltage U
LS
is ensured via micro-fuse. If the connector is used, this fuse
also provides protection of voltage U
A
.
If the available current of the supply voltage is lower (< 6.3 A) than the trigger current of the
micro-fuse, it is not triggered in case of error.
This is the case if an external power supply unit with low power is used.
Information on correct selection of the external power supply unit and replacement of the
micro-fuse can be found in the technical data.
2.10
Operator workstations
2.10.1
General information
This chapter describes the space requirement for operation of the basic module to be
ensured by the operator. Operation of the basic module in an office as well as in a training
room are considered.
In general, sufficient lighting of the workstations in compliance with „Lighting of work places
– DIN EN 12464-1“ must be ensured. According to DIN EN 12464-1, a light intensity of 500
Lux is recommended in the classification for „training institutions“ for training workshops,
exercise rooms and laboratories. The criteria of the following list must also be taken into
consideration.
Prevention of blinding
Sufficient evenness of indoor lighting
Low shading
Suitable light color
–
Color temperature of 4000 Kelvin is regarded to be suitable. This is neutral white.
–
To generate artificial daylight, a light color of approx. 6000 Kelvin can also be used.
This light, however, has a light shade of blue and is not considered as pleasant by
everyone.
The height of the worktable must be selected in such a way that ergonomic working is
possible. To ensure stability of the basic module, a minimum distance of 10 cm should be
ensured to the worktable edge in all sides. The spatial arrangement of the worktable may
vary depending on the task.
For example, the rear and sides of the working table may also end at the wall in an office. In
this case, the distance must only be ensured behind the operator. In general, an open
escape path to an emergency exit must be ensured.
Main switch
Fuse protection of
the supply voltages
U
LS
and U
A
for
extension modules