Power disconnect
- Units have power supplied whenever the power cord is inserted into the
power source, or when High Power-over-Ethernet (High PoE) power is provided over the
Ethernet CAT 5E/6 cable. The power cord is the main power disconnect device for switching
off the voltage for all units. When High PoE or PoE+ (820.3at) is used to power the unit, the
power is provided over the Ethernet cable, which is then the main power disconnect device
for switching off the voltage for all units.
Grounding:
- Connect outdoor equipment to the unit's inputs only after this unit has had its ground
terminal connected properly to a ground source.
- Disconnect the unit's input connectors from outdoor equipment before disconnecting the
grounding terminal.
- Follow proper safety precautions such as grounding for any outdoor device connected to this
unit.
U.S.A. models only - Section 810 of the National Electrical Code, ANSI/NFPA No.70, provides
information regarding proper grounding of the mount and supporting structure, size of
grounding conductors, location of discharge unit, connection to grounding electrodes, and
requirements for the grounding electrode.
Video loss -
Video loss is inherent to digital video recording; therefore, Bosch Security
Systems cannot be held liable for any damage that results from missing video information.
To minimize the risk of losing information, we recommend multiple, redundant recording
systems, and a procedure to back up all analog and digital information.
i
Notice!
Risk of water ingress
Securely seal all fittings and connection points between the device and all mounts to ensure a
liquid-tight seal. Failure to do so could allow water to enter the housing and damage the
device. Always use Teflon tape and sealant on connector threads of any mount (sold
separately by Bosch or user-supplied).
If a sealant is used, ensure that it is a neutral cure type. Sealants that release acetic acid may
harm electronics.
Use drip loops on the wiring outside the housing.
Always use Teflon tape and sealant on connector threads of any mount (sold separately by
Bosch or user-supplied).
1.5
Connection in applications
24 VAC power source:
This unit is intended to operate with a limited power source. The unit
is intended to operate at 24 VAC (if PoE+ is not available). User supplied wiring must be in
compliance with electrical codes (Class 2 power levels).
PoE:
Use only approved PoE+ devices. Power-over-Ethernet can be connected at the same
time as a 24 VAC power supply.
If auxiliary power (24 VAC) and PoE+ are applied simultaneously, the camera selects auxiliary
input and shuts off PoE+.