30
en | Connection
AUTODOME inteox 7000i - 2MP (in-ceiling)
2021-08 | 1.4 |
Installation Manual
Bosch Security Systems
Configuring Non-supervised Alarms (inputs 3 through 7)
You can configure alarms 3 through 7 as non-supervised Normally Open (N.O.) or Normally
Closed (N.C.) alarms.
Configuring a Normally Open Non-supervised Alarm
1.
Connect the alarm to the appropriate input (3 through 7) and ground at the camera.
Figure 10.3:
N.O. - Normally Open Non-supervised Connections
1
Dry Contact
3
Dome Connector
2
Alarm Inputs 3 to 7
4
Ground
2.
From
Configuration
, select
Alarm
>
Alarm Inputs
. For
Input
1, enter a
Name
for the
Alarm input
. In the field
Active
, select
N.O.
. Finally, select an
Action
. See the table below
for contact and condition details.
AUTODOME Programmed N.O.
Circuit
Alarm Indication
Open
Normal
Closed
Alarm
Configuring a Normally Closed Non-supervised Alarm
1.
Connect the alarm to the appropriate input (3 through 7) and ground at the camera.
Figure 10.4:
N.C. Normally Closed Non-supervised Connections
1
Dry Contact
3
Dome Connector
2
Alarm Inputs 3 to 7
4
Ground
2.
From
Configuration
, select
Alarm
>
Alarm Inputs
. For
Input
1, enter a
Name
for the
Alarm input
. In the field
Active
, select
N.C.
. Finally, select an
Action
.See the table below
for contact and condition details.
AUTODOME Programmed N.C.
Circuit
Alarm Indication
Open
Alarm
Содержание Autodome Inteox 7000i-2MP