AutoDome Easy
Connections
5
Bosch Security Systems, Inc.
Installation and Configuration Manual
December 06, 2006 | F01U074570 | 3.0
4.4
Alarm
The recommended optional alarm input cable is a 2-conductor, 18-22 gage cable, depending
on the distance. Refer to the wiring distance guide Table 4.1 on page 5.
Table 4.1
Wiring Distance Guide
5
Connections
Follow the instructions below to terminate all connections as described.
Table 5.1
Connection Cable Description
5.1
Connecting to the Biphase
The AutoDome Easy camera can be controlled remotely by an external device or control sys-
tem, such as a control keyboard, using biphase.
5.1.1
Direct Control
To connect the biphase configuration, do the following:
1.
Locate the cable assembly with a two (2) pin black mating connector on one end and the
brown and black flying leads on the other end.
2.
Connect the from the controller to the black lead and secure.
3.
Connect the biphase- from the controller to the brown lead and secure.
4.
Connect shield of the cable to the Head End controller.
Fig. 5.1
Biphase Direct Control
Wire Size
Maximum Distance
AWG
mm
feet meters
22
0.644
500 152.4
18 1.024
800 243.8
Color
Description
Black
Biphase (+)
Brown
Biphase (-)
Red
AC24 V / DC12 V
Orange
AC24 V / DC12 V
Blue
ALARM COMMON
Violet
ALARM IN
C-
C+
SHIELD
Head End
Biphase
Brown
Black
Not Connected X
AutoDome Easy