16
en | Troubleshooting Guide
AutoDome 100 Series Fixed Camera
F.01U.216.346 | 1.0 | 2011.04
User Manual
Bosch Security Systems, Inc.
Inside of
EnviroDome bubble
is foggy
–
Check the status of the Heater Module (
ON
-
66
-
ENTER
).
If status reports Heater No Power, then:
–
Turn off the power to the AutoDome.
–
Check the FX103 fuse in the Power Supply Box for power (24 V) to the heater module.
If O.K., then:
–
Check all wiring and connector pins to the heater module.
Low Voltage flashing
on monitor display
–
If using a non-Bosch power supply, confirm that it meets the Bosch AutoDome power
ratings. See the AutoDome Datasheet for specifications.
If O.K., then:
–
Check the mains input line voltage.
If O.K., then:
–
Check that the maximum wire length from the power supply has not been exceeded.
See the
VG5 AutoDome Installation Manual
.
If O.K., then:
–
Measure the AC voltage input to the camera while power is applied to the camera. The
voltage must be ≥ 21 VAC to stop the message.