If some burners have yellow flames while others have good
flames, it is likely that dust, lint or spider webs have partially
clogged the burner venturis. Contact a gas service person
to clean the remove and clean the burners.

Mineral Scale Build-up:

 The AquaStars heater, when

operated at lower temperatures settings, do not accumulate
mineral build-up. If however, the water has a high mineral
content, periodic descaling may  be necessary. The heating
coils should be flushed  with a descaling solution. Consult
your service person.

TROUBLE SHOOTING 

(see maintenance table)

Introduction

The AquaStar 125 B “S” burners are activated by a water
flow valve. Numerous water related problems can cause
this water valve to malfunction such as: Insufficient water
flow volume to activate the burners at its minimum flow
requirement; Dirt in the water flow valve causing it to
malfunction; Sediment build-up in faucet aerators, or shower
heads; Uneven pressures between cold and hot. (with single
lever faucets) Plumbing cross overs. These water flow related
problems can cause the heater to deliver less than its full
output, or to fail to ignite or to shut down completely.

Problems are stated in upper case, bold face. Most common
causes for the problems follow in order of likelihood. The
suggested solutions require that the cover be taken off. To
do this, remove incandescent particle tray and unscrew the
central screw located at the bottom of the front cover. Pull
main cover out toward you and lift up and out.

PILOT LIGHT WILL NOT LIGHT

1. No gas to the AquaStar

A. Gas cock on gas line may not be open.
B. Gas valve button has not been pushed in on “PILOT”
position (      ).
C. Gas regulator may be shut or damaged.

2. In-line AquaStar gas regulator jammed (usually on

LP gas)

Replace or unlock the regulator. 

Note:

 The regulator

furnished with the heater is designed for low gas pressure.
Excessive pressure will lock it up (propane only). Locking
usually happens if the gas pressure between the gas tank
(propane) and the water heater’s gas regulator has not been
reduced. See page 2 for recommended correct gas pressure.
To unlock a regulator, consult your gas supplier.

3. Pilot orifice clogged and/or air screen dirty, or pilot

gas filter is dirty.

Clogging of the pilot burner can be caused by dust and any
suspended matter contained in the ambient air.
Although the filters can lengthen the cleaning intervals, they
can never completely prevent such clogging. In consequence
the gas jet issuing from the pilot orifice is reduced and or
the air mixture is reduced. The pilot flame is weak and thus
can no longer heat the thermocouple sufficiently. For cleaning
purposes, the air filter screen is pulled off, washed and blown
out. The pilot orifice has likewise to be cleaned or exchanged.
Consult a gas service person to clean the pilot.

4. Air in the Gas Line
Note:

 Normally this is a problem only at the time of initial

installation, after the pipes have been worked on, or after a
propane tank has been allowed to empty, or after the heater
has been shut down for a long time.
Bleed all the air trapped in the gas line. Because of the very
small pilot orifice (especially on LP gas models), bleeding
out all the air could take several minutes. Depress the pilot
button (     ) and depress this button until all the air has
escaped, and the gas has arrived. During this process, press
repeatedely on the piezo ignition button until the pilot flame
has ignited.

PILOT LIGHTS BUT FLAME GOES OUT WHEN BUTTON
IS RELEASED

1. Pilot push button was not pushed in far enough or

was not held in long enough

Depress the pilot button. Hold it pushed in for at least 15
seconds to give time for the pilot flame to properly heat the
tip of the thermocouple.

2. Pilot flame improperly aimed or is too weak so it is

not properly heating the tip of the thermocouple.

The Pilot flame should be a sharp blue flame and aimed at
the tip of the thermocouple so that it envelops 10 mm (3/8
“) of the thermocouple tip. Pilot flame has to be properly
aimed at the thermocouple. See Fig 8.

3. Poor thermocouple connection at the electromagnet
Note:

 Electromagnet is part #8707201094 located on the

right side of the gas valve behind the piezo pushbutton
assembly. Check the tightness of the thermocouple
connection nut at the electromagnet: The Electro-magnet
connection is a large aluminum 17mm hex head nut. The
thermocouple end is a 5 mm brass nut which screws into
the 17 mm nut. Tighten the thermocouple nut snugly but not
too tight.

4. Poor circuit connections at the ECO. (Energy Cut-

Off overheat protection)

Oxidation or looseness of the ECO terminal connections
can result in millivolt current loss through the thermocouple
safety circuit. Clean terminals with very fine sand paper or
an eraser and reconnect ECO leads.

5. Faulty ECO (part #8707206017

)

If cleaning the terminals attached to the ECO did not fix the
problem, connect a jumper wire between the two wires and
try to  relight the pilot.  If the pilot flame now remains on,
replace the ECO.  If the flame still goes out when the button
is released, the ECO is not defective. Go to next step.

6. Faulty thermocouple (part #8747202083) or

electromagnet) Unless these 2 parts are at least 8 to
10 years old, it is very unlikely that they are faulty.
Before testing, reconfirm that #2 is absolutely correct,
and that all connections are clean and tight.

Содержание AquaStar 125B LPS

Страница 1: ... flammable combustible or corrosive vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department In...

Страница 2: ...off sensor Stainless steel burners with stabilized blue flame Built in corrosion resistant draft inducer Compact space saver mounts on a wall with two hooks Easily removable one piece cover Easy one person installation Adjustable water flow restrictor to ensure that water flow demand will not exceed the heating capacity of the heater Easy pilot flame lighting with push button piezo ignition BOSCH ...

Страница 3: ...INIMUM INSTALLATION CLEARANCES FROM COMBUSTIBLE AND NON COMBUSTIBLE MATERIALS FOR ALCOVE OR CLOSET INSTALLATIONS FRONT VIEW SIDE VIEW AQUASTAR MODEL 125BS MODEL 125BS TOP A 12 FRONT B 4 BACK 0 SIDES 4 FLOOR C 12 VENT DIAMETER 5 ...

Страница 4: ... these instructions when you install your heater In the United States The installation must conform with local codes or in the absence of local codes the National Fuel Gas Code ANSI Z223 1 NFPA 54 In Canada The Installation should conform with CGA B149 1 2 INSTALLATION CODES and or local installation codes 2 Carefully plan where you install the heater Correct combustion air supply and flue pipe in...

Страница 5: ...r combustion ventilation and dilution of flue gasses Appliances located in confined spaces The confined space must be provided with two permanent openings one commencing within 12 inches of the top and one commencing within 12 inches of the bottom of the enclosure Each opening must have a minimum free area of one square inch per 1000 Btu hr if all air is taken from inside the building 2000 Btu hr ...

Страница 6: ...ttached across a pair of studs and then the heater should be attached to the support boards See Fig 1 Expansion and contraction of piping due to changing water temperature in the pipes imparts movement to the heater which if mounted directly to a brittle friable board such as plasterboard can cause failure of mounting In earthquake prone zones BBTNA recommends that installers use a large washer an...

Страница 7: ... than 45 degrees from the vertical is considered horizontal Horizontal sections must slope upwards at least inch for every foot of its horizontal length and be properly supported Keep the horizontal section short and avoid too many elbows The minimum vertical gas vent height allowed is 6 feet horizontal vent connectors and elbows are not to be considered in the total gas vent height All gas vent s...

Страница 8: ...ney Also an approved thimble or collar must be used when penetrating a masonry chimney A Existing INTERIOR Masonry Chimney The metal gas vent pipe should be permanently mounted inside the masonry chimney Double wall Type B gas vent is recommended The masonry chimney may have to be tile or metal lined before the insertion of the gas vent pipe check local codes for clarification The lining material ...

Страница 9: ...lly being used the vent pipe is therefore cold except for the short durations when hot water is being used it is therefore very important that the venting and air supply be adequate to provide a good positive draft as soon as the burners turn on See venting guide on back page The AquaStar 125B S instantaneous water heaters have built in draft diverters and are designed for indoor installation only...

Страница 10: ...l Fuel Gas Code NFPA 54 ANSI Z223 1 No Additional Allowance is necessary for an ordinary number of fittings GAS LINE SIZING Fig 4 Nominal Iron Pipe Internal Length of Black Iron Pipe Feet Size Diameter inches inches 10 20 30 40 50 60 70 80 90 100 125 150 175 200 1 4 0 364 32 22 18 15 14 12 11 11 10 9 8 8 7 6 3 8 0 493 72 49 40 34 30 27 25 23 22 21 18 17 15 14 1 2 0 622 132 92 73 63 56 50 46 43 40 ...

Страница 11: ...ines to facilitate servicing the heater see Fig 7 For installation on a private well system with the use of a pressure tank the lowest pressure range setting recommended is 30 50 psi 2 07 3 45 bar Fig 5 Installation of Gas Pressure Regulator The pressure regulator provided with the heater is adjusted to deliver the proper gas pressure as indicated on the rating plate and in the manual for altitude...

Страница 12: ...ont cover of heater 1 STOP Read the safety information above on this plate 2 The gas valve must be turned off by depressing the gas valve off button 3 Wait five 5 minutes to clear out any gas If you smell gas STOP Follow B in the safety information above on this plate If you don t smell gas go to the next step 4 The pilot burner is located behind the peephole in the front center of the jacket dire...

Страница 13: ... for a hot bath Handwashing should not be done in water hotter than 112 and cooler for older adults young children or persons with sensory loss Remember that scalding can occur in 20 seconds with 135 water MAINTENANCE AND SERVICE see maintenance table on back of manual Approximately once a year the AquaStar should be checked and cleaned To remove the front cover first remove the incandescent parti...

Страница 14: ...s weak and thus can no longer heat the thermocouple sufficiently For cleaning purposes the air filter screen is pulled off washed and blown out The pilot orifice has likewise to be cleaned or exchanged Consult a gas service person to clean the pilot 4 Air in the Gas Line Note Normally this is a problem only at the time of initial installation after the pipes have been worked on or after a propane ...

Страница 15: ...t your plumber 7 Water valve parts may be dirty or components damaged Water valve and component parts must be totally free of dirt First check that the venturi is free of dirt particles In hard water areas mineral deposits can eventually 3 to 5 years in hard water areas corrode the water valve parts to a point where they will need replacing Any sign of moisture or corrosion at the joint of the wat...

Страница 16: ...o be performed see 7 under BURNERS DO NOT IGNITE WHEN HOT WATER IS TURNED ON HOT WATER TEMPERATURE FLUCTUATES UNIT DEACTIVATED 1 Unbalanced pressure in waterlines The added restriction caused by the Aquastar in the hot water system can result in uneven pressures between the cold and the hot In such cases when mixing cold water at the tap the lower hot water pressure may be overpowered by a much hi...

Страница 17: ...ly 3 Burner manifold gas pressure test nipple 4 Main gas burner 5 Pilot gas tubing 6 Gas valve 7 Piezo igniter 8 Location of pressure tap screw 9 Water valve 10 Gas inlet gas pressure test nipple 5 1 4 7 9 3 10 6 2 8 Fig 10 Diagram of AquaStar 125 BS ...

Страница 18: ...18 6 720 606 518 AQ 125 BS Fig 11 INTERIOR COMPONENTS DIAGRAM AND PARTS LIST ...

Страница 19: ...lot Tube 8 710 707 166 15 Thermocouple 8 747 202 083 16 Burner assembly washer 8 710 103 060 17 Gas valve 8 707 011 467 LP Gas valve 8 707 011 469 NG 18 Gas supply pipe 8 700 705 464 19 Electromagnet 8 747 201 094 20 Electromagnet washer 8 700 103 144 21 Gas filter 8 700 507 051 22 Thermocable 8 747 202 078 23 Thermostat 8 707 206 039 24 O ring Thermostat 8 700 205 101 25 O ring Thermostat 8 700 2...

Страница 20: ...20 6 720 606 518 Fig 12 Flow chart of Aquastar 125 BS ...

Страница 21: ...will furnish a replacement part free of charge Shipping costs In addition to supplying the replacement part s BBTNA will provide ground service delivery for these parts Expedited or upgraded shipping will be charged to the customer Service labor costs This warranty does not cover any labor costs associated with service removal or re installation of part s All such costs must be borne by the Purcha...

Страница 22: ...22 6 720 606 518 ...

Страница 23: ...23 6 720 606 518 ...

Страница 24: ... Cacia 3801 856 Aveiro PORTUGAL 3 1 e g a p e e s E L B A T E C N A N E T N I A M R A E Y Y R E V E S R A E Y 2 Y R E V E S R A E Y 5 3 Y R E V E E V L A V R E T A W E T A C I R B U L E V L A V R E T A W D L I U B E R N E E R C S R E T L I F R E T A W T C E P S N I Y L B M E S S A T O L I P T C E P S N I Y L B M E S S A T N E V T C E P S N I R E N R U B N I A M T C E P S N I Recycled paper 2006 BB...

Отзывы: