OPERATING INSTRUCTIONS

Before proceeding with the operation of the heater make
sure that the system is filled with water.
Open the cold water inlet supply to the heater fully.
Open a hot water faucet to permit the water to fill the heater
and the piping and to eliminate the air trapped in the system
Close the hot water faucet after the water flows freely and
all the air has escaped from the system.  The water heater
is now ready to operate.

FOR YOUR SAFETY READ BEFORE LIGHTING
THE PILOT

Warning

: If you do not follow these instructions

exactly, a fire or explosion may result causing property
damage, personal injury or loss of life

A.

This appliance  has a piezo-igniter  for lighting the pilot

burner. When lighting the pilot, follow these instructions
exactly.

B.

BEFORE LIGHTING smell all around the appliance area

for gas. Be sure to smell next to the floor because some gas
is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS
- Do not try to light any appliance.
- Do not touch any electric switch; do not use any phone

in your building

- Immediately call your gas supplier from a neighbor’s

phone. Follow the gas supplier’s instructions.

- If you cannot reach your gas supplier, call the fire

department.

C.

Use only your hand to push in or turn the gas control

buttons. Never use tools. If a button will not push in, check
to make sure the buttons are being pushed in the proper
sequence. Follow these instructions exactly. If control
button(s) are jammed, close the gas supply and call a
qualified service technician. Attempted forceful repair may
result in a fire or explosion.

D.

Do not use this appliance if any part has been under

water. Immediately call a qualified service technician to
inspect the appliance and to replace any part of the control
system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

 (as seen on front cover

of heater)

1.

STOP! Read the safety information above on this plate.

2.

The gas valve must be turned off by depressing the gas
valve off button (     ).

3.

 Wait five (5) minutes to clear out any gas. If you smell

gas, STOP! Follow “B” in the safety information above
on this plate. If you don’t smell gas, go to the next step.

4.

The pilot burner is located behind the peephole in the
front center of the jacket directly below this instruction
plate.

5.

Depress PILOT button (    ) and light pilot by pushing
PILOT INGITER button (     ).  This may have to be
repeated.

6.

Observe the pilot flame through the peephole. The pilot
button (    ) should be held down at least 15 seconds with
pilot burning.  When the pilot button is released the pilot
should continue to burn.

- If the gas valve button does not pop up when released,

stop and immediately call your service technician or gas
supplier.

- If pilot does not stay lit, repeat steps 1 through 6.
- If pilot will not stay lit after several tries, depress the OFF

button (    ), and call your service technician or gas supplier.

7.

 When lit, depress the ON button (        ). The heater will

now fire when water is drawn at a rate greater than the
threshold flow rate.

NOTE: If main burner should fail to ignite, make sure pilot
is burning. If not, repeat lighting steps 1 through 6.

TO TURN OFF GAS TO APPLIANCE

Depress the OFF button (    ) and close the gas supply to
the heater.

Connecting the pressure relief valve (PRV)

A listed pressure relief valve supplied with the heater must
be installed at the time of installation. No valve is to be
placed between the PRV and the heater. No reducing
coupling or other restriction may be installed in the discharge
line. The discharge line must be installed such that it allows
complete drainage of both the PRV and the line. The location
of the PRV must be readily accessible for servicing or
replacement, and be mounted as close to the water heater
as possible. See Fig 7. To install the PRV, a suitable fitting
connected to an extension on a “T” fitting can be sweated
to the hot water line.

Fig. 7 - Pressure Relief Valve

PIPE PRV TO
APPROPRIATE
DISCHARGE

HOT

COLD

Содержание AquaStar 125B LPS

Страница 1: ... flammable combustible or corrosive vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department In...

Страница 2: ...off sensor Stainless steel burners with stabilized blue flame Built in corrosion resistant draft inducer Compact space saver mounts on a wall with two hooks Easily removable one piece cover Easy one person installation Adjustable water flow restrictor to ensure that water flow demand will not exceed the heating capacity of the heater Easy pilot flame lighting with push button piezo ignition BOSCH ...

Страница 3: ...INIMUM INSTALLATION CLEARANCES FROM COMBUSTIBLE AND NON COMBUSTIBLE MATERIALS FOR ALCOVE OR CLOSET INSTALLATIONS FRONT VIEW SIDE VIEW AQUASTAR MODEL 125BS MODEL 125BS TOP A 12 FRONT B 4 BACK 0 SIDES 4 FLOOR C 12 VENT DIAMETER 5 ...

Страница 4: ... these instructions when you install your heater In the United States The installation must conform with local codes or in the absence of local codes the National Fuel Gas Code ANSI Z223 1 NFPA 54 In Canada The Installation should conform with CGA B149 1 2 INSTALLATION CODES and or local installation codes 2 Carefully plan where you install the heater Correct combustion air supply and flue pipe in...

Страница 5: ...r combustion ventilation and dilution of flue gasses Appliances located in confined spaces The confined space must be provided with two permanent openings one commencing within 12 inches of the top and one commencing within 12 inches of the bottom of the enclosure Each opening must have a minimum free area of one square inch per 1000 Btu hr if all air is taken from inside the building 2000 Btu hr ...

Страница 6: ...ttached across a pair of studs and then the heater should be attached to the support boards See Fig 1 Expansion and contraction of piping due to changing water temperature in the pipes imparts movement to the heater which if mounted directly to a brittle friable board such as plasterboard can cause failure of mounting In earthquake prone zones BBTNA recommends that installers use a large washer an...

Страница 7: ... than 45 degrees from the vertical is considered horizontal Horizontal sections must slope upwards at least inch for every foot of its horizontal length and be properly supported Keep the horizontal section short and avoid too many elbows The minimum vertical gas vent height allowed is 6 feet horizontal vent connectors and elbows are not to be considered in the total gas vent height All gas vent s...

Страница 8: ...ney Also an approved thimble or collar must be used when penetrating a masonry chimney A Existing INTERIOR Masonry Chimney The metal gas vent pipe should be permanently mounted inside the masonry chimney Double wall Type B gas vent is recommended The masonry chimney may have to be tile or metal lined before the insertion of the gas vent pipe check local codes for clarification The lining material ...

Страница 9: ...lly being used the vent pipe is therefore cold except for the short durations when hot water is being used it is therefore very important that the venting and air supply be adequate to provide a good positive draft as soon as the burners turn on See venting guide on back page The AquaStar 125B S instantaneous water heaters have built in draft diverters and are designed for indoor installation only...

Страница 10: ...l Fuel Gas Code NFPA 54 ANSI Z223 1 No Additional Allowance is necessary for an ordinary number of fittings GAS LINE SIZING Fig 4 Nominal Iron Pipe Internal Length of Black Iron Pipe Feet Size Diameter inches inches 10 20 30 40 50 60 70 80 90 100 125 150 175 200 1 4 0 364 32 22 18 15 14 12 11 11 10 9 8 8 7 6 3 8 0 493 72 49 40 34 30 27 25 23 22 21 18 17 15 14 1 2 0 622 132 92 73 63 56 50 46 43 40 ...

Страница 11: ...ines to facilitate servicing the heater see Fig 7 For installation on a private well system with the use of a pressure tank the lowest pressure range setting recommended is 30 50 psi 2 07 3 45 bar Fig 5 Installation of Gas Pressure Regulator The pressure regulator provided with the heater is adjusted to deliver the proper gas pressure as indicated on the rating plate and in the manual for altitude...

Страница 12: ...ont cover of heater 1 STOP Read the safety information above on this plate 2 The gas valve must be turned off by depressing the gas valve off button 3 Wait five 5 minutes to clear out any gas If you smell gas STOP Follow B in the safety information above on this plate If you don t smell gas go to the next step 4 The pilot burner is located behind the peephole in the front center of the jacket dire...

Страница 13: ... for a hot bath Handwashing should not be done in water hotter than 112 and cooler for older adults young children or persons with sensory loss Remember that scalding can occur in 20 seconds with 135 water MAINTENANCE AND SERVICE see maintenance table on back of manual Approximately once a year the AquaStar should be checked and cleaned To remove the front cover first remove the incandescent parti...

Страница 14: ...s weak and thus can no longer heat the thermocouple sufficiently For cleaning purposes the air filter screen is pulled off washed and blown out The pilot orifice has likewise to be cleaned or exchanged Consult a gas service person to clean the pilot 4 Air in the Gas Line Note Normally this is a problem only at the time of initial installation after the pipes have been worked on or after a propane ...

Страница 15: ...t your plumber 7 Water valve parts may be dirty or components damaged Water valve and component parts must be totally free of dirt First check that the venturi is free of dirt particles In hard water areas mineral deposits can eventually 3 to 5 years in hard water areas corrode the water valve parts to a point where they will need replacing Any sign of moisture or corrosion at the joint of the wat...

Страница 16: ...o be performed see 7 under BURNERS DO NOT IGNITE WHEN HOT WATER IS TURNED ON HOT WATER TEMPERATURE FLUCTUATES UNIT DEACTIVATED 1 Unbalanced pressure in waterlines The added restriction caused by the Aquastar in the hot water system can result in uneven pressures between the cold and the hot In such cases when mixing cold water at the tap the lower hot water pressure may be overpowered by a much hi...

Страница 17: ...ly 3 Burner manifold gas pressure test nipple 4 Main gas burner 5 Pilot gas tubing 6 Gas valve 7 Piezo igniter 8 Location of pressure tap screw 9 Water valve 10 Gas inlet gas pressure test nipple 5 1 4 7 9 3 10 6 2 8 Fig 10 Diagram of AquaStar 125 BS ...

Страница 18: ...18 6 720 606 518 AQ 125 BS Fig 11 INTERIOR COMPONENTS DIAGRAM AND PARTS LIST ...

Страница 19: ...lot Tube 8 710 707 166 15 Thermocouple 8 747 202 083 16 Burner assembly washer 8 710 103 060 17 Gas valve 8 707 011 467 LP Gas valve 8 707 011 469 NG 18 Gas supply pipe 8 700 705 464 19 Electromagnet 8 747 201 094 20 Electromagnet washer 8 700 103 144 21 Gas filter 8 700 507 051 22 Thermocable 8 747 202 078 23 Thermostat 8 707 206 039 24 O ring Thermostat 8 700 205 101 25 O ring Thermostat 8 700 2...

Страница 20: ...20 6 720 606 518 Fig 12 Flow chart of Aquastar 125 BS ...

Страница 21: ...will furnish a replacement part free of charge Shipping costs In addition to supplying the replacement part s BBTNA will provide ground service delivery for these parts Expedited or upgraded shipping will be charged to the customer Service labor costs This warranty does not cover any labor costs associated with service removal or re installation of part s All such costs must be borne by the Purcha...

Страница 22: ...22 6 720 606 518 ...

Страница 23: ...23 6 720 606 518 ...

Страница 24: ... Cacia 3801 856 Aveiro PORTUGAL 3 1 e g a p e e s E L B A T E C N A N E T N I A M R A E Y Y R E V E S R A E Y 2 Y R E V E S R A E Y 5 3 Y R E V E E V L A V R E T A W E T A C I R B U L E V L A V R E T A W D L I U B E R N E E R C S R E T L I F R E T A W T C E P S N I Y L B M E S S A T O L I P T C E P S N I Y L B M E S S A T N E V T C E P S N I R E N R U B N I A M T C E P S N I Recycled paper 2006 BB...

Отзывы: