![background image](http://html.mh-extra.com/html/bosch/al-2204-cv/al-2204-cv_original-instructions-manual_37929007.webp)
English |
7
Bosch Power Tools
1 609 92A 0F6 | (9.12.13)
Products sold in GB only
: Your product is fitted with a
BS 1363/A approved electric plug with internal fuse (ASTA
approved to BS 1362).
If the plug is not suitable for your socket outlets, it should be
cut off and an appropriate plug fitted in its place by an author-
ised customer service agent. The replacement plug should
have the same fuse rating as the original plug.
The severed plug must be disposed of to avoid a possible
shock hazard and should never be inserted into a mains sock-
et elsewhere.
Product Features
The numbering of the product features refers to the illustra-
tion of the battery charger on the graphics page.
1
Battery pack*
2
Green battery charge indicator
*Accessories shown or described are not part of the standard de-
livery scope of the product. A complete overview of accessories
can be found in our accessories program.
Technical Data
Operation
Starting Operation
Observe the mains voltage!
The voltage of the power
supply must correspond with the data given on the name-
plate of the battery charger. Battery chargers marked with
230 V can also be operated with 220 V.
Charging Procedure
The charging procedure starts as soon as the mains plug of
the battery charger is inserted into the socket and the battery
1
or the power tool with the slid on battery
1
is inserted on the
battery charger. The power tool cannot be switched on during
charging.
Firstly, place the battery
1
as shown in the figure onto the
front of the battery charger (
) and then press the battery
1
down at the rear (
). To remove the battery, proceed in re-
verse order.
Due to the intelligent charging method, the charging condi-
tion of the battery is automatically detected and the battery is
charged with the optimum charging current, depending on
battery temperature and voltage.
This gives longer life to the battery and always leaves it fully
charged when kept in the charger for storage.
Note:
The charging procedure is only possible when the bat-
tery temperature is within the allowable charging tempera-
ture range, see Section “Technical Data”.
Meaning of the Indication Elements
Flashing Battery Charge Indicator 2
The charging procedure is signalled by a
flashing
battery charge indicator
2
.
Continuous Lighting of the Battery Charge Indicator 2
Continuous lighting
of the battery
charge indicator
2
indicates that the
battery is fully charged
or
that the
temperature of the battery is not with-
in the allowable charging temperature range, and cannot be
charged for this reason. The battery is charged as soon as the
allowable charging temperature range is reached.
When the battery is not inserted,
continuous lighting
of the
battery charge indicator
2
indicates that the mains plug is in-
serted in the socket and that the battery charger is ready for
operation.
Battery Charger
AL 2204 CV
AL 2215 CV
Article number
2 607 225 2..
2 607 225 4..
Output voltage (automatic voltage detection)
V
14.4 – 21.6
14.4 – 21.6
Charging current
mA
430
1500
Allowable charging temperature range
°C
0 – 45
0 – 45
Charging time for battery capacity, approx.
100 %
100 %
– 1.0 Ah
min
150
45
– 1.3 Ah
min
180
55
– 1.5 Ah
min
207
63
– 2.0 Ah
min
290
85
Number of battery cells
4 – 6
4 – 6
Weight according to EPTA-Procedure 01/2003
kg
0.7
0.4
Protection class
/
II
/
II
Please observe the article number on the type plate of your battery charger. The trade names of individual battery chargers may vary.
OBJ_BUCH-190-007.book Page 7 Monday, December 9, 2013 9:00 AM