1 689 975 257
2019-05-15
|
Robert Bosch GmbH
20 | ACS 652 | Service phases
en
8.8
Filling refrigerant
i
The refrigerant in the internal refrigerant cylinder is
used for filling the vehicle air conditioning system.
i
Refrigerant can only be added to a vehicle air condi-
tioning system under a vacuum. The vacuum phase
must therefore be performed before filling.
i
Open EVHP1, EVHP2, EV 3 and EV 6.
Refrigerant flows from the internal refrigerant cylin-
der through valves V 4 and V 2, through the solenoid
valves EVHP1, EVHP2, EV3 and EV6
i
The filling quantity is checked by the scales (8),
which end the filling process after the quantity previ-
ously entered in the service process.
P1
EV5
EV3
EV6
3
F1
C
P2
HP
5
VU2
6
F2
9
4
EV7
10
7
V1
8
V3
V2
V4
V6
V5
M3
EV10
P
2
EV1
11
VU3
VU1
12
1
EV8
EV9
13
M2
T1
T2
M1
EVLP1
EVLP2
EVHP1
EVHP2
R1
R2
HOSE FLUSH MANIFOLD
SERVICE PORT
Name
Description
1
Fresh oil tank
2
Vacuum pump
3
Expansion valve
4
Evaporator/oil separator
5
Compressor oil separator
6
Compressor
7
Internal refrigerant cylinder
8
Refrigerant cylinder scales
9
Used oil bottle
10
Heat exchanger
11
UV dye bottle
12
Fresh oil scales
13
Used oil scales
EV1
Vacuum solenoid valve
EV3
Flow solenoid valve
EV5
Recovery solenoid valve
EV6
Filling solenoid valve
Name
Description
EV7
Oil drain solenoid valve
EV8
Oil injection solenoid valve
EV9
Contrast medium injection sole-
noid valve
EV10
Solenoid valve for separating
high and low pressure
EVHP1 High pressure solenoid valve
EVHP2 High pressure solenoid valve
EVLP1 Low pressure solenoid valve
EVLP2 Low pressure solenoid valve
F1
Coarse filter
F2
Combi filter
HP
High pressure
LP
LOw pressure
M1
Low pressure gage
M2
High pressure gage
M3
Internal refrigerant cylinder pres-
sure gage
Name
Description
P1
Pressure sensor
P2
Pressure switch
R1
Low pressure flushing connection
R2
High pressure flushing connection
T1
Low pressure hose
T2
High pressure hose
V1
Tank vapour side hose valve
V2
Tank liquid side hose valve
V3
Tank vapour side valve
V4
Tank liquid side valve
V5
Safety valve
V6
Non condensable drain valve
VU1
Oil non-return valve
VU2
One-way valve
VU3
UV contrast medium non-return
valve