Assembly 19/40
3 842 564 350/2020-06, MIT: PE 2/X, PE 2/H, PE 4,
Bosch Rexroth AG
7.5.2
PE 2/X, PE 2/H; assembling the position monitoring kit
Fig. 6:
554 089-08
80
80
100
100
B
0
4
1
2
5
3
M
D
= 1,2 Nm
T20
A
2
2x
SW13
C
M
D
= 25 Nm
4x
M
D
= 5 Nm
T30
SW5
M
D
= 10 Nm
1x
2x
Assembling the position monitoring set (example shown here on PE 2/H)
Required accessories
• Position monitoring kit
3 842 553 819
• IEC/EN 60947-5-2-2004
proximity switches,
3 842 537 995.
Please note:
The profi le height is marked
in mm (A), on the switching
fl ags on the bracket plate.
1.
Do not break the
required switching fl ags
on the bracket plate.
2.
Install the bracket plate
on the positioning unit.
3.
Install the distance place
in the bottom slot of the
section profi le.
4.
Install the switch
brackets on the
spacer plate.
5.
Install the proximity
switches.
(The switching distance
is determined by a stop
in the switch holder)
Proximity switches
B:
Detects lower
end position
C:
Detects upper
end position
EN