Only ever carry the dust extractor by the carrying handle
(6)
.
– Store the dust extractor in a dry room and secure it so
that it cannot be used by unauthorised persons.
– Put the castor brake
(11)
down to hold the castors
(12)
in place.
Rectifying faults
u
If a fault (e.g. a filter damage) occurs, the vacuum
cleaner must be switched off immediately. The fault
must be repaired before resuming operation.
Problem
Corrective measures
The suction turbine will not switch on. – Check the mains cable, mains plug, fuse, socket and fill level sensors
(35)
.
The mode selector switch
(5)
is set to "automatic start/stop".
– Set the mode selector switch
(5)
to the "vacuuming" symbol or switch on the
power tool plugged into the electric socket
(3)
.
The suction turbine switches off.
– Empty the container
(1)
.
The suction turbine will not switch on
again after emptying the container.
– Switch the dust extractor off and wait five seconds before switching it back on.
– Clean the fill level sensors
(35)
and the space between the fill level sensors
(35)
using a brush.
The suction power is decreasing.
– Remove any blockages from the suction nozzle, suction tube
(29)
, vacuum hose
(21)
or flat-pleated filter
(24)
.
– Change the disposal bag
(23)
or dust bag.
– Make sure the filter cover
(34)
is engaged correctly.
– Place the top part of the dust extractor
(8)
on correctly and close the catches
(9)
.
– Change the flat-pleated filter
(24)
.
Dust is escaping when vacuuming
– Check that the flat-pleated filter
(24)
has been fitted correctly.
– Change the flat-pleated filter
(24)
.
Automatic switch-off (wet vacuuming)
is not working.
– Clean the fill level sensors
(35)
and the space between the fill level sensors
(35)
using a brush.
Automatic switch-off will not work in the presence of non-conductive liquids or foam-
ing.
– Check the fill level regularly.
The filter cleaning function is not
working.
– Push the SFC+ switch
(18)
backwards (position
I
).
After-Sales Service and Application Service
Our after-sales service responds to your questions concern-
ing maintenance and repair of your product as well as spare
parts. You can find explosion drawings and information on
spare parts at:
www.bosch-pt.com
The Bosch product use advice team will be happy to help you
with any questions about our products and their accessor-
ies.
In all correspondence and spare parts orders, please always
include the 10‑digit article number given on the nameplate
of the product.
Great Britain
Robert Bosch Ltd. (B.S.C.)
P.O. Box 98
Broadwater Park
North Orbital Road
Denham Uxbridge
UB 9 5HJ
At www.bosch-pt.co.uk you can order spare parts or arrange
the collection of a product in need of servicing or repair.
Tel. Service: (0344) 7360109
E-Mail: [email protected]
You can find further service addresses at:
www.bosch-pt.com/serviceaddresses
Disposal
The vacuum cleaner, its accessories and packaging should
be recycled in an environmentally friendly manner.
Do not dispose of the vacuum cleaner along
with household waste.
Only for EU countries:
According to the European Directive 2012/19/EU on Waste
Electrical and Electronic Equipment and its implementation
into national law, vacuum cleaners that are no longer usable
must be collected separately and disposed of in an environ-
mentally friendly manner.
Bosch Power Tools
1 609 92A 7Z7 | (23.06.2022)
Содержание 3 601 JC3 060
Страница 3: ... 3 18 5 4 3 7 6 8 1 2 11 9 10 12 7 4 14 13 16 15 11 17 Bosch Power Tools 1 609 92A 7Z7 23 06 2022 ...
Страница 4: ...4 20 21 25 22 24 23 3m 27 26 19 29 28 19 20 21 22 1 609 92A 7Z7 23 06 2022 Bosch Power Tools ...
Страница 6: ...6 F H G I 26 27 7 28 21 5 19 32 3 20 20 L Boxx 22 33 19 7 1 609 92A 7Z7 23 06 2022 Bosch Power Tools ...
Страница 7: ... 7 J1 J2 K 34 14 24 24 35 35 Bosch Power Tools 1 609 92A 7Z7 23 06 2022 ...
Страница 8: ...8 L 22 29 13 15 16 25 28 17 4 1 609 92A 7Z7 23 06 2022 Bosch Power Tools ...
Страница 250: ...IV 1 609 92A 7Z7 23 06 2022 Bosch Power Tools ...