![Bosch 2000 Series Скачать руководство пользователя страница 47](http://html.mh-extra.com/html/bosch/2000-series/2000-series_program-entry-manual_39237047.webp)
2000 Series |
Program Entry Guide | 11.0
Point Codes
EN
| 47
Bosch Security Systems | 7/05 | 35114F
Table 9: Digit Selection Summary
Selection
Digit 1
Point Type
Digit 2
Alarm Response
Digit 3
Point Options
Digit 4
Device Address
Digit 5
Sensor Loop
0
Disabled
Set to 0 for RF
keypad.
No reports, No Swinger,
No Output
Set to 0 for RF keypad.
No Troubles, Not Cross Point,
Not Partner Point
Set Digit 3 to 0 for RF keypad.
On-Board
1
Fire
Reports, No Report
Delay, No Swinger, No
Output
Trouble Open, No Trouble
Short, No Double Knock, No
Cross Point, No Partner Point.
Device
Address 1
2
Fire with Alarm
Verify (use with
Point 1 only)
Reports, Report Delay,
No Swinger, No Output
No Trouble Open, Trouble
Short, No Double Knock, No
Cross Point, No Partner Point.
Device
Address 2
3
Buzz on Fault
Reports, Report Delay,
Swinger, No Output
Trouble Open, Trouble Short,
No Double Knock, No Cross
Point, No Partner Point.
Device
Address 3
4
24-hour, Visible
Reports, No Report
Delay, Swinger, No
Output
No Trouble Open, No Trouble
Short, Double Knock, No Cross
Point, No Partner Point.
Device
Address 4
5
24-hour, Invisible
No Reports, No Report
Delay, No Swinger,
Output
Trouble Open, No Trouble
Short, Double Knock, No Cross
Point, No Partner Point.
Device
Address 5
6
Controlled, All, Delay
Reports, No Report
Delay, No Swinger,
Output
No Trouble Open, Trouble
Short, Double Knock, No Cross
Point, No Partner Point.
Device
Address 6
7
Controlled, All No
Delay
Reports, Report Delay,
No Swinger, Output
Trouble Open, Trouble Short,
Double Knock, No Cross Point,
No Partner Point
Device
Address 7
8
Controlled, Part,
Delay
Reports, Report Delay,
Swinger, Output
No Trouble Open, No Trouble
Short, No Double Knock, Cross
Point, No Partner Point.
Device
Address 8
9
Controlled, Part, No
Delay
Reports, No Report
Delay, Swinger, Output
Trouble Open, No Trouble
Short, No Double Knock, Cross
Point, No Partner Point.
A
Keyswitch
No Trouble Open, Trouble
Short, No Double Knock, Cross
Point, No Partner Point.
A
B
Extended Delay, All
Trouble Open, Trouble Short,
No Double Knock, Cross Point,
No Partner Point
B
C
Extended Delay, Part
No Trouble Open, No Trouble
Short, No Double Knock, No
Cross Point, Partner Point.
C
D
Trouble Open, No Trouble
Short, No Double Knock, No
Cross Point, Partner Point.
D
E
No Trouble Open, Trouble
Short, No Double Knock, No
Cross Point, Partner Point.
E
F
Trouble Open, Trouble Short,
No Double Knock, No Cross
Point, Partner Point.
F
G to P
G to P
Содержание 2000 Series
Страница 1: ...EN Program Entry Guide Control Panels 2000 Series ...
Страница 14: ...2000 Series Program Entry Guide 3 0 Reports EN 14 Bosch Security Systems 7 05 35114F Notes ...
Страница 26: ...2000 Series Program Entry Guide 6 0 Open Close EN 26 Bosch Security Systems 7 05 35114F Notes ...
Страница 30: ...2000 Series Program Entry Guide 8 0 Bell EN 30 Bosch Security Systems 7 05 35114F Notes ...
Страница 34: ...2000 Series Program Entry Guide 10 0 Address Configuration EN 34 Bosch Security Systems 7 05 35114F Notes ...
Страница 50: ...2000 Series Program Entry Guide 11 0 Point Codes EN 50 Bosch Security Systems 7 05 35114F Notes ...
Страница 52: ...2000 Series Program Entry Guide 12 0 Point Text EN 52 Bosch Security Systems 7 05 35114F Notes ...
Страница 58: ...2000 Series Program Entry Guide 14 0 User Test EN 58 Bosch Security Systems 7 05 35114F Notes ...
Страница 62: ...2000 Series Program Entry Guide 16 0 RF Parameters EN 62 Bosch Security Systems 7 05 35114F Notes ...
Страница 64: ...2000 Series Program Entry Guide 17 0 Program Lock EN 64 Bosch Security Systems 7 05 35114F Notes ...