English–9
3 609 929 A44 • (05.09) T
4 MOUNTING
Operating and Storage Environment
The device is suitable exclusively for op-
eration at enclosed work sites.
For trou-
ble-free operation of the device, the al-
lowed ambient temperature should lie
between –5 °C and +50 °C (23 °F and
122 °F) at an allowed relative humidity of between 20
and 95 %, free of dew.
Mounting of a Screw Head
Hold the machine with the open-ended spanner
6
on
the spanner flats
5
of the angled head flange.
Never clamp the machine on the housing shells.
Place the angled drive head
3
in the desired position
on the flange and screw on with the open-ended
spanner
4
on the spanner flats
16
of the sleeve nut.
Hold the angled head flange with the open-ended
spanner
6
to prevent turning.
Suspension Device
With the hanging hoop
8
, the machine can be at-
tached to a suspension device.
Place the hanging hoop
8
included as an accessory
on the machine and allow it to engage in the slots
14
.
Regularly check the condition of the hanging hoop
and the hook of the suspension device.
Voltage adapter
9.6 V
12.0 V
14.4 V
Article number 0 602 490 ...
... 503
... 504
... 505
Voltage
V
9.6
12.0
14.4
Cable length
m
5
5
5
Weight in accordance with
EPTA-Procedure 01/2003
kg
lbs
0.15
0.33
0.15
0.33
0.15
0.33
Angled drive heads
■
1/4"
■
3/8"
■
3/8"
1/4"
QC
1/4"
Article number 0 607 ...
... 453 617 ... 453 620 ... 451 618 ... 453 618
... 453 630
Weight in accordance with
EPTA-Procedure 01/2003
kg
lbs
0.20
0.44
0.20
0.44
0.30
0.66
0.20
0.44
0.20
0.44
Screw head
QC
1/4"
Article number 0 607 ...
... 453 631
Weight in accordance with
EPTA-Procedure 01/2003
kg
lbs
0.20
0.44
Type 0 602 491 647/... 650/... 651/... 652/
... 656/... 669/... 671/... 673/
... 675
3
5
16
6
4
Type 0 602 491 647/... 650/... 651/... 652/
... 656/... 669/... 671/... 673/
... 675
8
14