9 708 069 951
Page3
Characteristic Data
Bosch 13P
Bosch 16P
Pilot orifice diameter mm
NG
0.30
0.30
LP
0.19
0.19
TG & TLP
0.56
N/A
Burner Injector Diameter mm
NG
1.25
1.30
LP
0.79
0.75
TG & TLP
2.25
N/A
Minimum water pressure for
maximum water flow
100 kPa
150 kPa
Maximum water flow litres per
minute @ 25°C rise
13
16
Nominal hourly gas
consumption Mj/h
100
130
Burner Pressure kPa
NG
0.87
0.71
LPG
2.60
2.60
Refer to rating label located on the bottom right hand corner of the back panel for additional
data.
Freezing
Weather
In areas where the atmospheric temperature may drop below
0°C, the heater must be drained to prevent damage by expansion of
freezing water. For appliances installed in locations where the
temperature falls below zero ° C for brief periods , the installation of an
EXOGEL expansion valve, part number H 707 060 151, will minimise the
possibility of damage to the appliance.
This water heater
MUST NOT
be installed in areas where the
temperature remains below 0°C for extended periods.
Conversion and Spare Parts
For spare parts or conversion of the heater to operate on a different gas
that for which it was originally manufactured, please contact your local gas authority,
authorised service agent or the manufacturer
Maintenance
We recommend that the appliance be inspected and cleaned by an authorised person
periodically, depending upon the frequency and duration of its operation, but never less than
once a year.
Exogel
Hot Water
1 Meter
minimum
25/10/2011