Wire brushes are intended to “clean” structural steel,
castings, sheet metal, stone and concrete. They are
used to remove rust, scale and paint.
Avoid bouncing and snagging
the wire brush, especially
when working corners, sharp edges etc. This can
cause loss of control and kick-back.
BRUSHING PRESSURE
1. Remember, the tips of a wire brush do the
work. Operate the brush with the lightest pressure
so only the tips of the wire come in contact with
the work.
2. If heavier pressures are used, the wires will be
overstressed, resulting in a wiping action; and if
this is continued, the life of the brush will be
shortened due to wire fatigue.
3. Apply the brush to the work in such a way that
as much of the brush face as possible is in full
contact with the work. Applying the side or edge of
the brush to the work will result in wire breakage
and shortened brush life.
Wire Brush Operations
CORRECT:
Wire tips doing
the work.
INCORRECT:
Excessive
pressure can
cause wire
breakage.
CORRECT:
Wire tips doing
the work.
INCORRECT:
Excessive pressure
can cause wire
breakage.
WIRE WHEEL BRUSH
WIRE CUP BRUSH
-14-
Service
Preventive maintenance
performed by unauth-
orized per so n nel may result in misplacing
of internal wires and components which
could cause serious hazard.
We recommend
that all tool service be performed by a Bosch
Factory Service Center or Autho rized Bosch
Service Station.
TOOL LUBRICATION
Your Bosch tool has been properly lubricated
and is ready to use. It is recommended that
tools with gears be regreased with a special
gear lubricant at every brush change.
CARBON BRUSHES
The brushes and commutator in your tool have
been engineered for many hours of
dependable service. To maintain peak
efficiency of the motor, we recommend every
two to six months the brush es be examined.
Only genuine Bosch replace ment brushes
specially designed for your tool should be used.
BEARINGS
After about 300-400 hours of operation, or at
every second brush change, the bearings
should be replaced at Bosch Factory Service
Center or Au thorized Bosch Service Station.
Bearings which become noisy (due to heavy
load or very abrasive material cut ting) should
be replaced at once to avoid overheating or
motor failure.
Cleaning
To avoid accidents
always dis connect the
tool from the power supply before cleaning
or performing any main tenance.
The tool
may be cleaned most effectively with
compressed dry air.
Always wear safety gog -
gles when cleaning tools with compressed
air.
Ventilation openings and switch levers must be
kept clean and free of foreign matter. Do not
at tempt to clean by inserting pointed objects
through openings.
Certain cleaning agents
and sol vents damage
plastic parts.
Some of these are: gasoline,
carbon tetrachlo ride, chlo rinated cleaning
solvents, ammonia and house hold detergents
that contain ammonia.
Maintenance