Minimum Measurement (see Fig.
)
The minimum measurement serves for determining the minimum distance
from a fixed reference point. It is an aid, for example, for the determination
of a vertical or horizontal distance. For minimum measuring, use the uni-
versal end piece
18
.
To switch to the minimum measuring mode, press the
button
1
re-
peatedly until the
symbol as well as the “MIN.” indicator appear in the
display.
To initiate the measurement process, press
the measurement button
7
completely down.
Move the laser spot back and forth over the
desired target point (e.g. a wall) such that the
rear end of the unit as the reference point of
the measurement remains at the same posi-
tion.
The minimum measured value is shown in the
upper right of the display.
By pressing the measurement button
7
, the minimum measuring is end-
ed. The current measured values as well as the minimum value are shown
in the display. The minimum value is automatically transmitted. A repeat-
ed pressing of the measurement button
7
starts the minimum measure-
ment anew.
Maximum Measurement (see Fig.
)
The maximum measurement servers for the determination of the maxi-
mum distance from a fixed reference point. It is an aid, for example, for
the determination of diagonals. For maximum measuring, use the univer-
sal end piece
18
.
To switch to the maximum measuring mode, press the
button
1
re-
peatedly until the
symbol as well as the “MAX.” indicator appear in the
display.
To initiate the measurement process, press
the measurement button
7
completely down.
Move the laser spot back and forth over the
desired target point (e.g. corner of a room)
such that the rear end of the unit as the refer-
ence point of the measurement remains at the
same position.
The maximum measured value appears in the
upper right of the display.
By pressing the measurement button
7
, the maximum measuring is end-
ed. The current measured values as well as the maximum value are
shown in the display. The maximum value is automatically transmitted. A
repeated pressing of the measurement button
7
starts the maximum
measuring anew.