42/56 Commissioning
Bosch Rexroth AG
, MCR Series 30, 31, 32, 33 and 41, RE 15215-01-B/11.2015
8.4 Final checks
After the running-in phase confirm the following conditions:
▶
Case drain pressure < 10 bar.
▶
Minimum pressure at ports
A
and
B
> 15 bar (general rule) or exact value as
stated in the data sheet, to avoid cavitation.
▶
Holding brake release pressure > 15 bar and < 30 bar (standard specification)
or exact values as stated on the installation drawing for all non-standard
specifications (SO versions).
▶
2 speed switching pressure:
For minimum and maximum 2 speed switching pressures refer to the appropriate
motor installation drawing.
▶
Case drain oil temperature < 85 °C. For operation above this temperature please
consult Rexroth engineering department in Glenrothes.
▶
Operating speeds, pressures and drive power are within current data sheet
recommendations.