![background image](http://html1.mh-extra.com/html/borroughs/wilsonstak/wilsonstak_installation-instructions-manual_2789088006.webp)
- 6 -
FIGURE 13
FIGURE 14
FLOOR ANCHORING
It is the responsibility of the user and installer to provide for
proper anchoring of shelving sections. Anchoring to any
part of the building structure requires that the local building
codes be met.
1. Make sure shelving range is in line and that the base
brackets are securely fastened to frames.
2. Plumb frames by using shims, as necessary, under
base brackets.
3. Drill into floor using holes in base brackets as a tem-
plate.
4. Install anchoring device (not provided) of the installer's
choice or as required for the particular floor condition.
See Figure 14.
TRIANGULAR GUSSETS (optional)
1. Before joining welded frames side-by-side, sandwich triangular gussets between frames
and base brackets and fasten with 1/4-20 x 1/2 Phillips pan head machine screws. See
Figure 13.
2. Plumb uprights by installing shims under either side of gusset.
3. Secure welded frames together with 1/4-20 x 1/2 Phillips pan head machine screws
and 1/4-20 x 5/8 Phillips pan head machine screws with 1/4-20 Keps nuts as shown.
See Figure 13.
FIGURE 14
00950-10
13974-00
07742-00
(NOT INCLUDED)