Problem/Report
Possible Cause
Suggested Action
No Water Dispenses
Closed water tap.
Open the tap.
The connection pipe to the tap is kinked or
pressed shut.
Adjust the path of the pipe to prevent kinks
or compression.
Only a Small Amount of Water
Dispenses
Obstructed filter.
Replace the filter.
Low inlet water pressure.
Please contact technical support.
Cold Water not Cold
Insufficient or obstructed ventilation.
Check the dispenser is positioned correctly
with nothing obstructing the ventilation
slots (see pages 12 - 14).
Frozen coil or issues with ice tank.
Adjust the thermostat to a higher
temperature. If this fails carry out the ice
tank defrosting procedure (see page 26).
No power supply.
Check the power cable is properly
connected to the dispenser, and that
any electrical components are operating
correctly
Water Leaks
Filter installed incorrectly.
Disconnect the power supply, close the
interception valve and replace the filter
(see pages 21 - 22).
Internal damage.
Disconnect the power supply, close the
interception valve and contact technical
support.
Sparkling Water not Carbonated
Lack of CO2.
Replace the CO2 bottle (see page 20).
Only CO2 is Expelled When
Dispensing Sparkling Water
Blocked water pump.
No water supply
Disconnect the power supply, close the
interception valve and contact technical
support.
Sparkling Water is Dispensed in
Splatters.
High CO2 pressure.
Reduce the CO2 pressure using the pres-
sure reducer.
Only a Small Amount of Sparkling
Water is Dispensed.
Low CO2 pressure.
Increase the CO2 pressure using the
pressure reducer.
Bleeping Noise - 7 bleeps.
Refrigeration alarm.
Disconnect machine from power and
contact technical support.
Bleeping Noise - 6 bleeps every
15 seconds.
Pump blockage.
Locate and repair accordingly.
30 & 60-Litre Fault Diagnosis
Advanced Troubleshooting